Télécharger Imprimer la page

Buderus Logacool AC166i MS CN Serie Notice D'utilisation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

HIntended use
The indoor unit is intended for installation inside the building with
connection to an outdoor unit and further system components, e.g.
controls.
The outdoor unit is intended for installation outside the building with
connection to an indoor unit or units and further system components,
e.g. controls.
The air conditioning system is intended for commercial/residential use
only where temperature deviations from adjusted set points do not lead
to damage of living beings or materials. The air conditioning system is
not suitable to set and maintain desired absolute humidity levels
precisely.
Any other use is considered inappropriate. Any damage that may result
from misuse is excluded from liability.
For installation at special locations (underground garage, mechanical
rooms, balcony or at any semi-open areas):
▶ First refer to the requirements for the installation site in the technical
documentation.
HGeneral dangers posed by the refrigerant
▶ This appliance is filled with refrigerant. If the refrigerant gas gets into
contact with fire, it may generate toxic gas.
▶ Have the system inspected and serviced regularly by an approved
contractor.
▶ If there is a possibility that refrigerant has escaped, thoroughly
ventilate the room and notify the approved contractor.
HConversion and repairs
If modifications to the air conditioning system are not carried out
correctly, this can result in personal injury and/or material damage.
▶ Have work carried out only by an approved contractor.
▶ Do not make any changes to the outdoor unit, indoor unit or other
parts of the air conditioning system.
▶ Disconnect the air conditioning system from the power supply before
carrying out any maintenance work.
HNotices on handling the system
If the air conditioning system is used incorrectly, this could impair your
health.
▶ Do not stand directly in the airflow for any length of time.
▶ Ensure that the room temperature is suitable for all people in the
room, including babies, children, elderly, bedridden or disabled
people.
▶ Never insert objects into the unit, you could injure yourself.
If the unit is handled incorrectly, this can lead to reduced performance
and also damage to the unit and personal injury.
▶ Do not block the air inlets and outlets of the unit.
▶ Shut doors and windows when the unit is in operation.
▶ Protect the indoor unit from water ingress.
▶ Check the outdoor unit mounting rack periodically for wear and to
make sure it is firmly in place.
▶ Do not apply any weight to the outdoor unit, e.g. objects or persons.
▶ Keep dust, steam and moisture in the installation room of the indoor
unit to a minimum.
▶ Do not use highly-flammable gases, e.g. from spray cans, in the
vicinity of the units.
▶ If there appears to be something wrong with the air conditioner
(burning smell or faulty cable for example), stop using it immediately
and disconnect the power supply.
HSafety of electrical devices for domestic use and similar
purposes
The following requirements apply in accordance with EN 60335-1 in
order to prevent hazards from occurring when using electrical
appliances:
Logacool AC166i MS CN... – 6721877104 (2023/10)
"This appliance can be used by children of 8 years and older, as well as
by people with reduced physical, sensory or mental capabilities or
lacking in experience and knowledge, if they are supervised and have
been given instruction in the safe use of the appliance and understand
the resulting dangers. Children shall not play with the appliance.
Cleaning and user maintenance must not be performed by children
without supervision."
"If the power cable is damaged, it must be replaced by the manufacturer,
its customer service department or a similarly qualified person, so that
risks are avoided."
1.3
Notices regarding these instructions
The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: .
2.2
Specifications of remote control
Power infeed
2 AAA batteries
Signal range
8 m
Permissible ambient
-5 °C ... 60 °C
temperature
Table 10
2.3
Operating temperature range
Room temperature
Cooling
16 ... 32 °C
Heating
0 ... 30 °C
Dehumidifying
10... 32 °C
Table 11
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
If the humidity is more 80 %, condensation may form at the air
outlet. To prevent this, open the vertical ventilation flaps as wide as
possible (vertical relative to the ground) and set a high fan output.
2.4
Use with multi-split air conditioner
The indoor unit can be used in a system with multi-split air conditioner.
In this case, the following functions are deactivated:
• Energy saving functions ECO and GEAR
• Self-cleaning (I cleanI clean)
• Noise reduction (Silent ModeSilent Mode)
• Manual operation
• Detection of leaking refrigerant
2
Product Information
Outside temperature
-15... 50 °C
-15... 24 °C
0... 50 °C
11