Product Information
2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2
Scope of delivery
Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter (black) and bio filter (green)
[4]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[5]
Remote control
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
5-core communication cable (optional accessory)
[10] 4 anti-vibration couplings for the outdoor unit
2.3
Product dimensions and minimum clearances
2.3.1
Indoor unit and outdoor unit
Figures 2 to 4.
2.3.2
Refrigerant lines
Key to Fig. 5:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 5, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CL5000i 26 E
CL5000i 35 E
1) Gas side or liquid side
2) Measured from lower edge to lower edge.
Table 2 Pipe Length and Drop Height
54
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
Unit type
Liquid side [mm]
CL5000i 26 E
6.35 (1/4")
CL5000i 35 E
6.35 (1/4")
Table 3 Pipe diameter depending on unit type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
Table 4 Alternative pipe diameter
Specification of the pipes
Min. piping length
Standard piping length
Additional refrigerant when the piping
length exceeds 5 m
Piping Thickness
Thickness of insulation against heat
Material of insulation against heat
Table 5
2.4
Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant.
The device is hermetically sealed. You will find the information on the
refrigerant according to the Regulation (EU) No 517/2014 on
fluorinated greenhouse gases in the operating instructions of the device.
Information for the installer: If you refill refrigerant, enter the additional
charge size and the total charge size of the refrigerant in the table
"information on refrigerant" of the operating instructions.
Climate 5000i – 6721824787 (2021/09)
Pipe size
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
Alternative pipe diameter [mm]
6
10
3 m
5 m
12g/m
≥ 0.8 mm
≥ 6 mm
Polyethylene foam

Publicité