Nicols STROB 3000 DMX Notice D'utilisation page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cables cannot
transmit control data reliably over long runs. 24 AWG cables are suitable for runs up to 300
meters. Use heavier gauge cable and/or an amplifier for longer runs.
DMX CONTROL OPTIONS
The DMX control options are selected on the MODE dipswitches at the rear of the fixture.
1-CH DMX :
Allows to strobe from 0 flash per second to maximum flash rate and trigger the blinder effect
from the controller. To select 1-channel DMX operation, set ON pin 5 and OFF pin 1 to 4.
CHANNEL
1
3-CH DMX :
Provides control of flash intensity, flash duration and flash rate for more advanced control than 1-
channel mode. To select 3-channel DMX operation, set pins 1 to 5 OFF.
CHANNEL
1
2
3
Rate
VALUE
0 - 5
0 - 1
6 - 249
2 - 98
250 - 255
98 - 100
VALUE
Rate
0 - 5
0 - 1
6 - 255
2 - 100
0 - 255
0 - 100
0 - 5
0 - 1
6 - 255
2 - 100
FUNCTION
Blackout
Flash rate, slow to fast
Continuous "Blinder" effect
FUNCTION
Flash intensity
Blackout
Minimum to maximum
Flash duration
0 - 650 ms @ 50 Hz AC, or
0 - 530 ms @ 60 Hz AC
Flash rate
No flash (single flash with ch. 1)
0.5 - 17 Hz @ 50 Hz AC, or
0.6 - 20 Hz @ 60 Hz AC

Publicité

Table des Matières
loading

Table des Matières