Télécharger Imprimer la page

CEVIK PRO CE-PROMIG 130N Manuel D'instructions page 55

Publicité

Les langues disponibles

Les langues disponibles

EN
9. CONTROLS AND OPERATION OF MACHINE.
TIG torch not included as standard.
9.1 Controls for MIG welding
9.1.1 Switch the machine on using the mains power switch Wait 5 seconds for the digital control program to
load up.
9.2.3 Now stretch the torch lead and handle out as straight as possible from the machine and select the wire
check function. This will start the feed motor running at full speed to feed the wire through the torch liner.
9.2.4 Once the wire comes out past the end of the torch neck, pull the torch trigger or press any button on
the display to stop the automatic wire feed.
9.2.5 Close the wire feed cover door.
9.2.6 Replace the welding tip (25) and conical nozzle (24) back onto the torch neck and trim off any excess
wire. You are now ready to weld!
9.3. MMA/STICK mode operation.
Note - MMA/Stick Welding requires an MMA lead set .
9.2. Feeding the wire.
9.2.1 Remove the conical nozzle (24) and the welding tip (25)
from the torch. The conical nozzle is removed by turning
clockwise and pulling off simultaneously. The welding tip
threads out of the tip adapter.
9.2.2 With the wire feed cover door still open pull the torch
trigger (20) and check that the wire is feeding smoothly through
the feed roller and into the torch.
9.3.1 Connect Earth Lead Quick Connector (23) to the positive (+) output
welding terminal (6).
9.3.2 Connect Earth Clamp (22) to the work piece. Contact with
workpiece must be strong contact with clean, bare metal, with no
corrosion, paint or scale at the contact point .
9.3.3 Connect the ARC/electrode holder lead (28) to the negative (-)
welding output terminal (8). Note – some welding electrode types utilize
different connection polarity. If in doubt, contact the electrode
manufacturer.
9.3.4 Turn the machine on at the Mains Power Switch
55

Publicité

loading