ENGLISH
Note: Do not
overtighten.
Figure 7. Sweep Elbow
LXi Heater
Figure 8. LXi
Heater, CV Filter and SHP Pump Sweep Elbow Installation
a. Switch off the circuit breaker to the equipment
and open the air relief valve on top of the filter
(leave it open during this procedure).
NOTE: If the filter is below pool level, close the suction and
return line valves to isolate the filtration system. Remove
the drain plug from the filter. Let the water drain from the
filter.
b. Be sure there is a minimum distance of 7½
inches between the center of the pump
outlet port and the filter inlet bulkhead to
accommodate the sweep elbow(s). See Figure 8
for recommended installation configuration.
NOTE: The SHP pump shown in Figure 8 is for reference only.
The Jandy Pro sweep elbow also works with the MHP
and PHP series pumps.
NOTE: Be sure to use 2" or 2½" schedule 40 PVC pipe.
c. Clean the cut ends of the pipe and both ends of
the sweep elbow(s) with an appropriate NSF
approved All Purpose cleaner/primer. Glue the
sweep elbow(s) onto the cut pipe ends using
an appropriate All Purpose NSF approved
adhesive/glue.
Page 8
Jandy
Sweep Elbow
P/N SEAQL1001
®
Cartridge Pool Filters | Installation & Operation Manual
®
WARNING
Follow all filter manufacturer's instructions.
NEVER attempt to assemble, disassemble
or adjust the filter when there is
pressurized air in the system. Starting the
pump while there is any pressurized air
in the system can cause product failure
or also cause the filter lid to be blown off,
which can cause death, serious personal
injury or property damage.
7½"
Minimum
CV Filter
NOTE: Zodiac recommends Weld-On 724 PVC to CPVC Cement
to glue Schedule 40 PVC.
d. After the glue is cured, close the pressure relief
valve on top of the filter, start the system and
check for proper water flow.
6. Make all plumbing connections in accordance
with local plumbing and building codes. Filter
connections are provided with an o-ring seal. To
avoid damage to the o-rings, use only a silicone
base lubricant on the o-rings. Do not use pipe joint
compound, glue or solvent on inlet/outlet union
coupling nuts.
7. Keep piping tight and free of leaks. Pump suction
line leaks may cause air to be entrapped in filter
tank or loss of prime at the pump. Pump discharge
line leaks may show up as dampness or jets of
water.
8. Support the inlet/outlet pipes independently to
prevent any undue strains on the filter valve.
9. Connect the pipes using the unions supplied with
the filter. Do not use Teflon tape or pipe dope on
any unions. Assemble the unions dry and hand
tighten. See Figure 6.
Sweep Elbow
P/N SEFL1002
SHP
Pump