Technical Data; Accuracy; Ambient Conditions; Dimensions, Weights - Balluff BTL7-A/C/E5-M-SF-F Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
BTL7-A/C/E5 _ _ -M _ _ _ _ -SF-F _ _
Magnetostrictive Linear Position Sensor – Rod Style
10

Technical data

10.1

Accuracy

The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-S-3112-4Z float.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Typical
Sampling rate
Dependent on nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
1)
Velocity detectable max.
10.2

Ambient conditions

Ambient temperature
2)
Process temperature
3)
Storage temperature
Relative humidity
Pressure rating (BTL rod)
Pressure rating (float)
pH values
Process media
Cleaning media
Restrictions on process and
cleaning media
Degree of protection per
IEC 60529
www.balluff.com
±10 µm
250 µs to 2 ms
500 µs
±50 µm
±0.01% FS
≤ 30 ppm/K
10 m/s
–40 °C...+85 °C
≤ 130 °C
–40 °C...+100 °C
< 90%,
non-condensing
≤ 300 bar
see Tab. 11-1
2...13.2
1.6...13.2
(1.6...2 for ≤ 20 min)
conditionally resistant to
chloride corrosion
IP67
10.3

Dimensions, weights

Rod diameter
Nominal length
Weight (depends on length)
Housing material
Flange material
Rod material
Rod wall thickness
Housing mounting
10.4

Supply voltage (external)

Voltage, stabilized
Residual ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protected
4)
Overvoltage protection
Dielectric strength (GND to
housing)
10.5

Output

BTL7-A... Output voltage
Load current
BTL7-C... Output current
Load resistance
BTL7-E... Output current
Load resistance
Short-circuit resistance
10.6

Input

Programming inputs La, Lb
Overvoltage protection
Nominal stroke = 500 mm, float in middle of measuring range
1)
Ambient temperature: maximum permissible temperature at the BTL
2)
housing.
Process temperature: maximum permissible temperature of the rod below
3)
the flange (with media contact).
Certain production processes require e.g. sterilization at 120 °C...130 °C
for 0.5...1 hours (see Tab. 11-1).
4)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
10.2 mm
≤ 2500 mm
Approx. 2 kg/m
Stainless steel
Stainless steel
Stainless steel
2 mm
1 1/2" Tri-Clamp per
SSI 3A standard 74-06
and seal
BAM SE-XA-002-D38,
1-S (see Accessories on
page 20)
10...30 V DC
≤ 0.5 V
pp
≤ 120 mA
≤ 500 mA
to 36 V
to 36 V
500 V AC
0...10 V and 10...0 V
≤ 5 mA
0...20 mA/20...0 mA
≤ 500 Ω
4...20 mA/20...4 mA
≤ 500 Ω
Signal cable to 36 V
Signal cable to GND
10...30 V DC,
high-active
to 36 V
english
19

Publicité

Table des Matières
loading

Table des Matières