Télécharger Imprimer la page

Harvia HGX20XW Instructions D'installation Et D'utilisation page 35

Publicité

EN
2. INSTRUCTIONS FOR INSTALLATION
1. Steam nozzle
2. Manual discharge valve
3. Pipe adapter 18 mm-G½"
4. Sediment cup
5. Control panel
6. Temperature sensor
Optional parts and devices:
7. Automatic discharge valve
8. Connection part for fragrance pump
9. Fragrance pump
10. Fragrance
Figure 4.
Abbildung 4.
Model
Output
Recommended steam room size (m
Modell
Leistung
Empfohlene Dampfkabinengröße (m
Light wall
(acrylic, etc.)
Leichtbauwand
(Acryl, usw.)
kW
HGX20XW
2,2
2–4
HGX45XW
4,5
2–5
HGX60XW
5,7
2,5–8
HGX90XW
9,0
6–12
HGX110XW 10,8
10–14,5
HGX150XW 15,0
12–19,5
Table 2.
Installation details
Tabelle 2. Montageinformationen
2.3.
1,5–4,0 bar
)
3
)
3
Tiled light wall
Tiled stone wall,
Geflieste
etc.
Leichtbauwand
Geflieste
Steinwand, usw.
2–4
2–4
2–4
2–3,5
2–6
2–5
4,5–10
3–8
8–12
6–10
10–16
8–13,5
DE
2. INSTALLATIONSANLEITUNG
1. Dampfdüse
2. Manuelles Auslassventil
3. Rohradapter 18 mm-G½"
4. Auffangbecher für Ablagerungen
5. Bedienfeld
6. Temperaturfühler
Optionale Teile und Zubehör:
7. Automatisches Auslassventil
8. Verbindungsstück für die Duftkonzentratpumpe
9. Duftkonzentratpumpe
10. Duftkonzentrate
Steam
230 V 1N~
output
capacity
Dampf-
ausgabe-
Cable
kapazität
Kabel
kg/h
mm
2
2,0
3 x 1,5 10
5,5
3 x 6
7,6
3 x 6
12,0
-
14,6
-
20,1
+
400 V 3N~
Fuse
Cable
Fuse
Sicherung
Kabel
Siche rung
A
mm
A
2
-
-
25
5 x 1,5
3 x 10
25
5 x 1,5
3 x 10
-
5 x 2,5
3 x 16
-
5 x 2,5
3 x 16
5 x 6
3 x 25
35

Publicité

loading

Ce manuel est également adapté pour:

Hgx45xwHgx60xwHgx90xwHgx110xwHgx150xw