8.1 RESETTING A SWITCHSTONE-STD
• Press and hold the reset button for 5 seconds to
reset the SwitchStone-STD
• After holding the reset button, the reset procedure
takes 10 seconds to complete
BUS
C
R1
POWER
IN 1
OUT 1
SWITCHSTONE
C
NO
IN1
• Once the reset is complete, all LED's will run
counterclockwise in a circle
8.2 RESET TING A SLIMSTONE-X
Write down the 9-digit serial number which can be
found on the side of the SlimStone-X
• Press and hold [C] for 5 seconds
• [C] and [#] start flashing
• Enter the 9-digit serial number of the keypad
• Press [#] to confirm
• If the reset was successful, [1] or [6] will start
flashing while [#] remains lit
[1] Create a new network.
Proceed as described in paragraph 5
[6] Join an existing network.
Enter the Master PIN of the network and
the SlimStone-X will be added. An error
message will occur (lef-right flashing) if no
network configuration is available
SlimStone-X
BUS
NO
NC
BUS
IN 2
OUT 2
R2
NC
IN2
SlimStone-X *SSX-000 000 000*
• If you want to create a new network, the
SwithStone-STD also needs to be reset first
9. REPLACE SLIMSTONE-X
• Physically remove the SlimStone-X from the
network
• Physically connect the new SlimStone-X to the
network
• After powering up, the digits [1] and [6] will
start flashing on the keypad (SlimStone-X) and
[#] will be permanently lit. In case this pattern
is not shown, please reset the keypad before
proceeding, according to the procedure
described in paragraph 8.2
• Select [6]
• Enter the Master PIN code, press [#] to confirm
• The SlimStone-X will now try to connect to the
SwitchStone-STD. This process could take up to
10 seconds
• If successful, the SlimStone-X will go to the normal
operating mode. If the procedure fails, verify the
cabling and try again
10. FUNCTIONING OF
SLIMSTONE-X
Installation process, as described in paragraph 5
10.1 ENTER A CORRECT CODE
• Enter a PIN code (min. 4 - max. 8 digits)
• Press [#] to confirm
• In case the code is only valid for 1 relay, the relay
will be activated immediately
• In case the PIN code is valid for multiple
relays, the numbers of the available relays will
start flashing. Press a number to activate the
corresponding relay
• The selected relay number and [C] light up.
(default relay time is 8 seconds)
• The relay selection menu will disappear after 5
seconds. The digits will blink from top to bottom
and the SlimStone-X is ready for a new code
10.2 ENTER A WRONG CODE
• Enter a wrong PIN
• Press [#] to confirm
• All lights flash twice, indicating a wrong code has
been entered
EN
13