• All digits flash once from top to bottom
• You will return to the main menu of the
programming mode. The digits of the menu options
and the cancel button [C] will start flashing
When two different codes or a wrong code
EN
length is entered, all keys will flash three times,
indicating the code setting hasn't been saved.
Try again. [1] will remain lit
A code can be removed by de-selecting all
relay numbers before confirmation
7.3 SET HOLD TIME RELAY [2]
• Access programming mode (see 7. 1 )
• Press [2] and confirm with [#]
• The digits of the numbers of the available relays
start flashing. Press the relay number that you want
to configure and confirm with [#]
• Choose the desired switching duration:
— a value between 1 and 98 for a timed relay
(= relay remains active for the chosen number
of seconds)
— '0' for pulse mode (= the relay is activated for
500 ms)
— '99' for bistable mode (= the relay remains
activated until another code is entered)
• Enter a value between 0 and 99, and confirm
with [#]. When a correct value has been correctly
entered, all digits flash once from top to bottom
• You will return to the main menu of the
programming mode. The digits of the menu options
and the cancel button [C] will start flashing
In case an invalid time is entered, all keys will
flash three times. Menu [3] remains activated
The default time is set to 8 seconds
7.4 SET LIGHTING MODE [5]
• Access programming mode (see 7. 1 )
• Press [5] and confirm with [#]
• There are 3 lighting modes. The number of the
selected mode is permanently lit
• Choose the desired lighting mode:
[1] Always Dimmed (20% brightness)
[2] Always On (full brightness)
[3] Auto-dim (default)
The brightness of the lighting is dimmed to
20% after 45 seconds inactivity. As soon as
a key is pressed, the lighting will be back at
full brightness for 45 seconds minimum
• Press [1], [2] or [3] and confirm with [#]. When
all digits flash from top to bottom, your choice is
correctly saved
12
• You will return to the main menu of the
programming mode. The digits of the menu options
and the cancel button [C] will start flashing
Menu option 7 and 8 are used to set up
networks with multiple SlimStone-X and/or
multiple SwitchStone-STD. Please visit following
link for more information to set up a
multi-device network:
7.5 SENDING JOIN REQUEST [7]
• Access programming mode (see 7. 1 )
• Press [7] and confirm with [#]
• Enter the serial number of the non-configured
device or enter no serial number to join all
connected and unconfigured devices
• Press [#] to confirm
7.6 REMOVE DEVICE FROM
NETWORK [8]
• Access programming mode (see 7. 1 )
• Press [8] and confirm with [#]
• Enter the serial number of the device you want to
remove from the network or enter no serial number
to remove all offline devices
• Press [#] to confirm
The removed devices can no longer be joined in
an existing network. A complete reboot of both
SwitchStone-STD and SlimStone-X is required
and a new network need to be created
8.
FACTORY RESET UPON LOSS
OF MASTER PIN
When the Master PIN is lost, both the SwitchStone-
STD and SlimStone-X need to be reset. The detailed
procedures are described in paragraph 8. 1 and
8.2. Once both devices are reset, repeat the system
installation process, as described in paragraph 5