OR SHOWERS. This means that it cannot be installed in the are-
as marked as VOLUME 1 in picture 1.
The IPX4 protection level is guaranteed, provided the rubber cap
that protects and closes the USB port is in place and closed pro-
perly.
During function, place the heater in a safe position:
-
at least 1m far from inflammable objects or furnitures;
-
leaving not less than 1m of free space in front of the heater;
-
not located immediately below a socket-outlet.
Do not leave animals or children touch or play with the appliance.
Pay attention! The air outlet grille gets hot during operation (more
than 90°C)
Do not use the heater in rooms with explosive gas or while using
inflammable solvents or varnish or glues.
If the cordset is damaged and you have to change it, do not do
the job yourselves! Take the product to an after sales authorised
repair centre or to a person with similar skill and knowledge, in
order to avoid any risk of danger.
The appliance must be positioned so that the plug is always ac-
cessible.
Do not mount the product on walls made of synthetic material.
2. W
all Mounting
Only fix the heater in vertical position with the air outlet grid downward;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth
connection.
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the
floor. The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum
gap between the contacts that allows complete disconnection according to excess voltage III category conditions.
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 2. Never
install the product so that the distance between the floor and the lower side of the product is less than 600 mm:
-
Drill four 6mm diameter holes in the wall, as shown in picture 3;
-
Insert the four wall plugs supplied with the product;
-
Fix the wall bracket with the 4 screws as shown in picture 4.
To fix one or both the towel rails to the product, before hanging it to the wall bracket, proceed as follows:
-
Insert at the extremity of the towel rails the M6 x 12mm screw and fix to it the T-nut as shown in picture 5-A;
-
T-nut must be just slightly screwed and not tighten to the end so that it will enter inside the profile of the
towel warmer (picture 5-B);
-
Slide the towel rail from the top being careful not to scratch the glass or the mirror (picture 5-C);
-
Slide the towel rail until the desired positin is reached (picture 5-D);
-
Move the towel rail towards the front of the heater untill the T-nuts previously fixed enter the lateral profiles
of the product (picture 6-A/B);
-
Fully tighten the screws at the extremity of the rail until the T-nut rotates and locks inside the profile (picture
6-C).