Item:
FL-30PCS-KNTR
FL-60PCS-KNTR
FL-100PCS-SFYK
FL-100PCS-SFYK-HV
FL-200PCS-SFYK
FL-200PCS-SFYK-HV
FL-290PCS-SFYK
FL-290PCS-SFYK-HV
FLOOD LIGHT POWER & COLOR SELECTABLE
4. Yoke Mounting:
Figure 19
Wiring Diagram:
Black: ACL
Green:
White: ACN
**NOTE: THESE INSTRUCTIONS DO NOT ADDRESS ALL PERMUTATIONS THAT MAY EXIST IN INSTALLATION, MAINTENANCE, AND OPERATING ENVIRONMENT.
**REMARQUE : CES INSTRUCTIONS NE TRAITENT PAS DE TOUTES LES PERMUTATIONS QUI PEUVENT EXISTER DANS L'INSTALLATION, LA MAINTENANCE ET L'ENVIRONNEMENT D'EXPLOITATION.
**NOTA: ESTAS INSTRUCCIONES NO ABORDAN TODAS LAS PERMUTACIONES QUE PUEDEN EXISTIR EN EL ENTORNO DE INSTALACIÓN, MANTENIMIENTO Y OPERACIÓN.
©2023 Southwire Company, LLC. All rights reserved.*Registered Trademark & ™Trademark of Southwire Company, LLC.
INSTALLATION INSTRUCTIONS
Figure 20
Purple:Dim+
Pink:Dim-
800-666-2852 | TOPAZ-USA.COM
1. Drill 2 holes 3-15/16" apart around the input power wires.
See Figure 13.
2. Mount the bracket onto the crossbar with bolts (wooden
walls with lag bolts and for concrete or brick walls,
hammer in expansion bolts and mount the bracket). See
Figure 14.
3. Feed wires into the junction box. Connect wires according
to the wiring diagram and close the junction box.
1. Make sure AC power is turned off before beginning any
electrical work.
2. Connect input wires Black to line, White to neutral, Green
to ground, Dim+ (Purple) to Dim+ on the dimmer, and
Dim- (Pink) to Dim- on the dimmer.
Note: If not using the dimming feature, do not connect the
dimming wires. Terminate and cap the Dim+ and
Dim- wires separately.