Item:
FL-30PCS-KNTR
FL-60PCS-KNTR
FL-100PCS-SFYK
FL-100PCS-SFYK-HV
FL-200PCS-SFYK
FL-200PCS-SFYK-HV
FL-290PCS-SFYK
FL-290PCS-SFYK-HV
FLOOD LIGHT POWER & COLOR SELECTABLE
Instructions For Installing Photocell:
Light
Installation of LED Fixture:
1. Slipfitter Mounting:
Adjusting Bolt
Light
Locking bolt
AM Bracket
Wire
Support
Figure 13
2. Knuckle Mounting:
Fixture
Knuckle
Mount
Junction
Box
Figure 15
3. Trunnion Mounting:
1.5"
10mm
Figure 17
©2023 Southwire Company, LLC. All rights reserved.*Registered Trademark & ™Trademark of Southwire Company, LLC.
INSTALLATION INSTRUCTIONS
AC Photocell
Socket
AM Bracket
Light
Support
Figure 14
Fixture
Knuckle
Mount
Junction
Box
Figure 16
Figure 18
800-666-2852 | TOPAZ-USA.COM
1. After mounting, place the keyed photocell in the
receptacle on top.
Note: If not using the photocell feature a shorting cap must
be used in its place.
2. Verify the photocell is facing North. If not, remove the
photocell from the receptacle. Remove the 2 screws in the
receptacle and turn (at 90-degree increments) until
proper aiming is achieved. Reinstall the 2 screw to the
receptacle, then install the photocell.
1. Loosen the (4) locking bolts on the slipfitter mount.
Connect the wires according to the Wiring Diagram. Push
excess wiring into the pole. See Figure 13.
2. Place the bracket onto the pole and secure the 4 locking
bolts. See Figure 14.
Note: Maximum pole outer diameter is 2-3/8".
1. Run wires into the junction box (Not Supplied) and screw
the knuckle mount into the 1/2" NPT knockout. See Figure
15.
2. Make the wiring connections according to the Wiring
Diagram.
3. Close the junction box. See Figure 16.
1. Drill 2 holes 1.5" apart around the input power wires. See
Figure 17.
2. Mount the bracket onto wooden walls with lag bolts and
for concrete or brick walls, hammer in expansion bolts
and mount the bracket.
3. Feed wires into the junction box. Connect wires according
to the Wiring Diagram and close the junction box. See
Figure 18.