TECHNICAL SPECIFICATIONS
Model
Dimensions (mm)
Absorption surface
Area (m
Opening area (m
Absorbent area (m
Net Weight (kg)
Transfer fluid volume (l)
Absorbent material
Casing
Insulation
Pressure drop (mbar)
Stagnation temperature
Maximum pressure (bar)
Maximum working pressure (bar)
Maximum flow (l/hour)
Sealing
TRANSPORT AND HANDLING
- Transport and store the collectors correctly packaged and protected.
- Wherever possible, the collectors should be supported on pallets.
- Do not place the collector on unstable surfaces.
- The collector should not be supported by the side connection (racors) to avoid malfunctions.
- Do not stack more than 5 collectors under storage conditions.
GENERAL POINTS
Generally, panels are installed facing the equator. When this is not possible, deviations of ± 10º will be allowed.
The optimum angle of inclination towards the horizon is Latitude ± 10º. (Min. 20 º Max. 70º)
The installation should be assembled and put into operation by an authorised technician.
14
ADVANCE 1.8
1930x930x90
Selective layer
2
)
1,84
2
)
1,65
2
)
1,62
34
2,36
Low Fe content tempered glass
1,0
203
20
10
100
ASSEMBLY PROCEDURE
ADVANCE 2.5
CLASSIC 1.8
1988x1218x90
1930x930x90
2,42
1,84
2,24
1,65
2,19
1,62
41,5
32,5
3
2,36
Ultrasound soldered copper
Glass fibre
1,8
1,0
203
203
20
20
10
10
120
100
EPDM & Silicone
CLASSIC 2.5
1988x1218x90
Black
2,42
2,24
2,19
43
3
Tempered glass
1,8
203
20
10
120