continue SETTING AND OPERATION
5.4 Running Capacity Setting
Hold
for more than 3 seconds to unlock the
1
screen.
Press
to start. The pump will run at 80% of the
running capacity at the initial startup after the
2
self-priming.
Press
or
to set the running capacity between
30%~100%, each step by 5%.
3
backwashing, users can set a high running capacity
according to the size of filter.
Hold
for more than 3 seconds to read the
4
real-time power.
5.5 Timer mode
The pump's on/off and running capacity could be commanded
by timer, which could be programmed daily as needed.
Maximum 4 timers can be set on the control panel.
1
Enter timer setting by pressing
2
Press
or
to set the local time.
Press
to confirm and move to timer-1
When enter the timer-1 setting, the timer indicator 1
will light up. "StA"will be shown on the screen.
Press
to proceed and then press
3
start time of timer-1 (with 30 minutes for each step),
press
to confirm.
When the start time of timer 1 is confirmed, "End"will be
shown on the screen. Press
4
press
or
to set the end time of timer-1
(with 30 minutes for each step), press
When the end time of timer 1 is confirmed, "SPd"will be
shown on the screen. Press
5
press
or
to set the running capacity of timer-1
(30% - 100%, each step by 5%), press
When the timer 1 setting is completed, repeat steps 3 – 5
6
to complete the setting of timer 2 – 4.
5.6 Parameter Setting
Under off mode, hold both
Restore factory setting.
3 seconds.
Check the software
Under off mode, hold both
version.
3 seconds.
Under ON mode, hold both
Manual priming.
3 seconds.
Under OFF mode, hold both
for 3 seconds to enter the parameter
setting. The parameter address
Enter parameter
(on the left) and default setting value
setting as shown.
(on the right) will flash alternately on
the screen. Users can press
to adjust the current value, and hold
both
parameter address. It will exit the
parameter setting after 10 seconds
without operation.
8
INVERFLOW
For the purpose of
.
or
to set the
to proceed and then
to confirm.
to proceed and then
to confirm.
for
for
for
or
for 3 seconds to the next
Note:
a. When the running capacity is adjusted, the system will save the
latest parameter automatically.
b.When setting 100% speed, the pump will increase the speed
automatically if the pipeline resistance is high, but will not exceed
the rated power of each model.
NOTE:
When timer mode is activated, if the set time period contains the
current time, the pump will start running according to the set running
capacity and the corresponding timer indicator (1 or 2 or 3 or 4) will
stay on, and the set running capacity will be shown on the screen.
If the set time period does not contain the current time, the timer
indicator (1 or 2 or 3 or 4) that isabout to start running will light up
and flash, and the current time will be shown on the screen.
All 4 time periods should be set in chronological order.
Overlap setting of time will be considered invalid, the pump will only
run based on the previous valid setting.
During the timer setting, if users want to return to the previous
setting item, hold both
4 timers, they can hold
for 3 seconds after completing the
setting of the specific timer, the system will automatically save the
current set value and activate the timer mode.
When the timer mode is on, users can check the setting of each timer.
Press
to select the specific timer (1 or 2 or 3 or 4), and the
corresponding timer indicator will light up. Then press
the start time, end time, and running capacity setting of the
selected timer.
Users can hold
for 3 seconds to read the real-time power and
exit timer mode by holding
Parameter
Description
Address
Digital input 2
1
Digital input 3
2
Digital input 4
3
Self-priming/
Backwash
4
capacity
Enable or disable the
priming that occurs at
5
start.
Self-primming
6
recheck time
for 3 seconds. If users don't need
to check
for 3 seconds.
Default
Setting Range
Setting
30~100%, by 5%
100%
increments
30~100%, by 5%
80%
increments
30~100%, by 5%
40%
increments
80~100%, by 5%
100%
increments
25:enables
25
0:disables
1-15min by 1min
2min
increments