MAINTENANCE
 Replace the spark plug cap.
 Reinstall the engine cover. Tighten knob to secure.
Cleaning the Exhaust Port and Muffler
Depending on the type of fuel used, the type and amount
of lubricant used, and/or your operating conditions, the
exhaust port and muffler may become blocked with carbon
deposits. If you notice a power loss with your gas-powered
products, you may need to remove these deposits to restore
performance. We highly recommend that only qualified service
technicians perform this service.

Spark Arrestor

See Figure 14.
NOTICE
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and
local fire prevention regulations. Check with appropriate
authorities. Contact customer service or an authorized
dealer to purchase a replacement spark arrestor.
The spark arrestor must be cleaned or replaced every 50
hours or yearly to ensure proper performance of your product.
Spark arrestors may be in different locations depending on
the model purchased. Please contact your nearest service
dealer for the location of the spark arrestor for your model.
To clean the spark arrestor:
 Loosen the screws on the rear panel. Remove the rear
panel and set aside.
 Loosen the clamp securing the spark arrestor in place.
 Remove the spark arrestor and gently clean using a wire
brush.
 Replace the spark arrestor and rear panel. Ensure the
clamp and all screws are tightened securely.
Draining Fuel Tank/Carburetor
See Figures 15 - 16.
To help prevent gum deposits in the fuel system, drain the
fuel from the tank and carburetor before storing.
Draining the Fuel Tank
NOTICE
Remove all lubricant from the unit before draining the
fuel tank. Failure to do so could cause damage to the
unit.
 Remove the fuel cap.
 Tilt the generator and allow fuel to drain from the fuel tank
into an approved container.
 When the fuel has drained from the tank, replace the fuel
cap.
Draining the Carburetor
 Loosen the knob at the side of the engine cover. Remove
cover and set aside.
 Place the on/off/choke dial in the RUN/RE-START position.
 Pull the carburetor drain tube out of the spout on the gen-
erator base and place into a container suitable to catch
fuel.
 Loosen the carburetor drain screw and allow fuel to drain
completely into the container.
 Retighten drain screw securely.
 Reinstall the carburetor drain tube into the drain spout on
the generator base.
Make sure the drain tube is fully seated into the drain
spout. Failure to fully seat the drain tube could allow fuel
to leak into the bottom of the generator housing, which
could cause serious personal injury and property damage.
 Place the on/off/choke dial in the OFF/STORAGE position.
NOTE: Consult hazardous waste management guidelines in
your area for the proper way to dispose of used fuel.
Transporting
 Verify the on/off/choke dial is in the OFF/STORAGE position.
 Close the vent on the fuel cap by rotating the fuel cap lever
to the OFF position.
 Make sure engine and exhaust of unit is cool.
 Keep unit level to prevent fuel spillage.
 Do not drop or strike unit or place under heavy objects.
 If transporting in a vehicle, drain the fuel tank, place the on/
off/choke dial in the OFF/STORAGE position and securely
restrain the generator.
 Provide a plastic sheet or absorbent pad below the gen-
erator to catch any drips of fuel or lubricant.