INSTALLATION
performance is directly dependent on an adequate
draft from your chimney. Do not connect this unit
to a chimney flue serving another appliance.
The following recommendations may be useful for
the installation of your chimney:
1.
It must rise above the roof at least 3' (0.9m) from
the uppermost point of contact.
2. The chimney must exceed any part of the
building or other obstruction within a 10'
(3.04m) distance by a height of 2' (0.6m).
3. The installation of an interior chimney is always
preferable to an exterior chimney. Indeed, the
interior chimney will, by definition, be hotter
than an exterior chimney, being heated up by
the ambient air in the house. Therefore the
gas which circulates will cool more slowly, thus
reducing the build-up of creosote and the risk
of chimney fires.
4. The draft caused by the tendency for hot air to
rise will be increased with an interior chimney.
5. Using a fire screen at the extremity of the
chimney requires regular inspection to ensure
that it is not obstructed thus blocking the draft,
and it should be cleaned when used regularly.
FACTORY BUILT CHIMNEY
Listed
Chimney
Combustible
Ceiling Joists
Chimney
Connector
Listed Cap
Maintain 2"
Storm Collar
Clearance
Flashing
Listed
Chimney
Ceiling
Support
*
Chimney
Connector
To Stove
Floor
Protector
Attic
Insulation
Sheild
Specified
Clearance
Ceiling
Support
To Stove
* Refer to Clearance
to Combustibles
Combustible Wall
When a metal prefabricated chimney is used, the
manufacturer's installation instructions must be
followed. You must also purchase (from the same
manufacturer) and install the ceiling support
package or wall pass-through and "T" section
package, firestops (where needed), insulation
shield, roof flashing, chimney cap, etc. Maintain
proper clearance to the structure as recommended
by the manufacturer. The chimney must be the
required height above the roof or other obstructions
for safety and proper draft operation.
MASONRY CHIMNEY
Ensure that a masonry chimney meets the
minimum standards of the National Fire Protection
Association (NFPA) by having it inspected by a
professional. Make sure there are no cracks, loose
mortar or other signs of deterioration and blockage.
Be sure to the chimney cleaned before the stove is
installed and operated. When connecting the stove
through a combustible wall to a masonry chimney,
special methods are needed.
Concrete Cap
1" Clearance
with Firestop
Rafter
Flashing
Combustible Wall
Thimble
12" of Brick
To Stove
Floor
Protector
9
© 2024 United States Stove Company
Fireclay Flue
Liner With
Airspace
Flashing
Eave
1" Clearance
Sheathing
Airtight
Cleanout
Door

Publicité