Télécharger Imprimer la page

Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Numbers:
AW2020
AW2020-BL
AW2020-WP
AW2020-L
Report Number: F19-476R3
Tested Per EPA M28R & ASTM E2515 and CSA B415.1-10
Certified to UL 1482-2022, CAN/ULC S627:2023
Mobile home / transportable building approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
• AW2020-BP
• AW2020-W
• AW2020-P
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
854108-1206N
www.P65warnings.ca.gov
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour Ashley AW2020

  • Page 1 Owner’s Instruction and Operation Manual Model Numbers: AW2020 • AW2020-BP AW2020-BL • AW2020-W AW2020-WP • AW2020-P AW2020-L Report Number: F19-476R3 Tested Per EPA M28R & ASTM E2515 and CSA B415.1-10 Certified to UL 1482-2022, CAN/ULC S627:2023 Mobile home / transportable building approved * All Pictures In This Manual Are For Illustrative Purposes Only.
  • Page 2 The instructions pertaining to the installation of your wood stove comply with UL1482-2022 and CAN/ ULC S627:2023 standards. This manual describes the installation and operation of the Ashley, AW2020, AW2020-BP, AW2020-BL, AW2020-W, AW2020-WP, AW2020-P, AW2020-L wood heater. This heater meets the 2020 U.S.
  • Page 3 INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4 ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 TOOLS AND MATERIALS ASH PAN ASSEMBLY You will need a drill with a 1/8” bit to install sheet metal Remove ash pan from firebox. Under the firebox, screws into connector pipe. A 5/16” socket/wrench there are two brackets;...
  • Page 5 ASSEMBLY INSTRUCTIONS FIREBRICK CONFIGURATION AIR DEFLECTOR ASSEMBLY Replace the Firebrick as shown in the illustration. Use the provided screws to attach the air deflector to the rear of the unit. INSTALLATION SAFETY NOTICE SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, •...
  • Page 6 INSTALLATION A wood stove must never be installed in a hallway pipe. or near a staircase, since it may block the way in • The chimney connector must not pass through case of fire or fail to respect required clearances. an attic or roof space, closet or similar concealed space, a floor, or a ceiling.
  • Page 7 INSTALLATION mobile home/transportable building. This type of FOR USE IN MOBILE HOME/TRANSPORTABLE installation is also required in air tight houses and BUILDINGS houses with negative pressure problems. You can • WARNING! DO NOT INSTALL IN SLEEPING purchase this option through your heater dealer. ROOM.
  • Page 8 INSTALLATION chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance. An inadequate draft may cause back-puffing into the room and “plugging” of the chimney. An inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints.
  • Page 9 INSTALLATION performance is directly dependent on an adequate When a metal prefabricated chimney is used, the draft from your chimney. Do not connect this unit manufacturer’s installation instructions must be to a chimney flue serving another appliance. followed. You must also purchase (from the same The following recommendations may be useful for manufacturer) and install the ceiling support the installation of your chimney:...
  • Page 10 INSTALLATION COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS METHOD - 12” (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent.
  • Page 11 INSTALLATION chimney connector by way of sheet metal support NOTES: plates at both ends of chimney section. Cover • Connectors to a masonry chimney, excepting opening with and support chimney section on both method B, shall extend in one continuous section sides with 24 gage minimum sheet metal supports.
  • Page 12 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTIONS: HOUSE FIRE HAZARDS WARNING: EXPLOSION HAZARD • DO STORE WOOD FLOOR • NEVER CHEMICALS, GASOLINE, PROTECTOR, UNDERNEATH STOVEPIPE(S) GASOLINE-TYPE LANTERN FUEL, OR ANYWHERE WITHIN CLEARANCES TO KEROSENE, CHARCOAL LIGHTER FLUID, OR COMBUSTIBLE SURFACES SPECIFIED FOR SIMILAR FLAMMABLE LIQUIDS TO START OR THIS APPLIANCE.
  • Page 13 OPERATION INSTRUCTIONS TESTING YOUR WOOD 12. Paper products, cardboard, plywood, particleboard. The prohibition against burning • When the stove is thoroughly warmed, place one these materials does not prohibit the use of fire piece of split wood (about five inches in diameter) starters made from paper, cardboard, sawdust, parallel to the door on the bed of red embers.
  • Page 14 OPERATION INSTRUCTIONS NOTICE - INITIAL BURNS TO CURE PAINT BECAUSE HIGH OPERATING TEMPERATURES, THIS APPLIANCE IS COATED WITH A SPECIAL HIGH TEMP PAINT WHICH REQUIRES A SERIES OF LOW TO MEDIUM BURNS TO FULLY CURE FOR DURABILITY AND A LIFETIME OF SERVICE.
  • Page 15 OPERATION INSTRUCTIONS VISIBLE SMOKE the air control fully open (in the “HI” position) for 13 minutes. After 15 minutes begin to push the air The amount of visible smoke being produced can be control in to the “Low” position (air control fully an effective method of determining how efficiently pushed in).
  • Page 16 CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED • Leave the air control fully open for about 5 min. CAUTION: every time you reload the stove to bring it back DO NOT OVERFIRE APPLIANCE. YOU ARE to proper operating temperatures. The secondary OVERFIRING IF ANY PART OF THE APPLIANCE combustion can only take place if the firebox is GLOWS RED.
  • Page 17 CHIMNEY MAINTENANCE SMOKE & CO MONITORS the stores where wood stoves are sold. The glass should be washed only when cold. Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous GASKET CARE gas when exposed to elevated concentrations for extended periods.
  • Page 18 OPTIONAL CB36 BLOWER WIRING DIAGRAM DANGER: SHOCK HAZARD DISCONNECT POWER SOURCE CAUTION: MOVING PARTS CAN BEFORE INSTALLATION AND WHENEVER SERVICING CAUSE INJURY. DO NOT OPERATE BLOWER ASSEMBLY. WITH COVER REMOVED. WHITE / BLACK / BLACK / BLANC NOIR NOIR BLACK / BLACK / BLACK / NOIR...
  • Page 19 REPAIR PARTS Part # Description 40292A 6” Flue Collar 88042 Rope Gasket 1/4” 25845 Air Deflector 26060 Rear Shield 891492 Blower Assembly (CB36) 610926 Rear Pedestal 29068 Pedestal 29065 Pedestal Front 610922 Pedestal Base Weldment 610925 Ashpan Housing 40566 Cast Iron Leg 29071 Ash Pan 891137...
  • Page 20 REPAIR PARTS Part # Description 88375 Upper Baffle Board 88374 Main Baffle Board 894134 Rear Tube Assembly 894135 Middle Tube Assembly 894136 Front Tube Assembly 894127 Brick Retainer 23783 Firebrick (1-1/4 x 2-9/16 x 9) 27338 Firebrick (1.25” x 2.25” x 4.5”) 89066 Firebrick (4-1/2 x 9) 24103...
  • Page 21 SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 22 NOTES © 2024 United States Stove Company...
  • Page 23 NOTES © 2024 United States Stove Company...

Ce manuel est également adapté pour:

Aw2020-blAw2020-wpAw2020-lAw2020-bpAw2020-wAw2020-p