Control options
UNIT STATUS
The unit status can be selected from the Aidoo device, enabling on/off control of both the room
thermostat and the circuits, as well as domestic hot water (DHW).
OPERATION MODES
The selectable modes are: Cooling mode and Heating mode.
DHW CONTROL
The manufacturer's units allow you to manage domestic hot water (DHW) production status
control. The "Powerful" function can be activated in DHW production status control, which
forces the DHW to reach a temperature that has been preset in the configuration of the unit. If
DHW is turned off, it will not be possible to activate this parameter.
WORKING SETTINGS
The manufacturer's units can operate in both room temperature mode and in water supply
temperature mode.
The Aidoo device can regulate the temperature in one or two circuits, both in room
temperature mode and in supply temperature mode.
SET-POINT TEMPERATURE
The unit temperature will depend on the working settings:
In room temperature mode, the thermostat room temperature will be selected, and in
supply temperature mode, the water supply temperature at which the unit is to operate will
be selected.
The DHW temperature can be selected within the ranges set by the unit's own main
thermostat.
The temperature limits cannot be obtained via protocol. The Airzone device will always offer
the default values configured in the unit's thermostat and changing these limits may lead to
the undesirable behavior of the device.
EN
11