Diagnostic LEDs
EN
Factory reset
This button allows you to restore the device to factory settings by pressing it continuously for
more than 10 seconds.
Reset of the device
Allows you to reset the device without removing any previously set configuration parameters.
Digital input
Configurable voltage free input to switch the unit on/off.
Note: it is recommended that the wiring of the digital inputs be routed through a separate
conduit.
Relay output (12V)
12V relay output for the control of the system's ancillary elements.
Note: for more information, refer to "Relay activation logic (12V)" in the "Control Options"
section.
Power supply input
12 Vdc input that enables providing power to the Aidoo Pro device.
The 230 Vac - 12 Vdc power supply is supplied with the device.
6
Connecting to a Wi-Fi network
Connected to a Wi-Fi network
Connected to the server
Not configured
Cloud Communications
Microprocessor activity
Power supply
Transmission of data to the indoor unit
Reception of data from the indoor unit
Meaning
Blinking
Steady
Steady
Off
Blinking
Blinking
Steady
Blinking
Blinking
Green
Blue
-
Red
Green
Red
Red
Green