Features (Rear Panel)
UPS System: This self-contained unit houses the UPS system's power and control components as well as its
1
internal batteries.
Independent, Detachable Power Distribution Unit (PDU): This self-contained unit houses the UPS system's input and
2
output components along with a bypass switch. When the switch is set to bypass the PDU can be completely removed from
the power/battery module for routine power/battery maintenance without disrupting power to the connected loads. While this
switch is set to bypass, connected equipment will receive unfiltered AC mains power, but the equipment will not receive battery
power in the event of a blackout.
AC Input Cord: Connects directly to wall receptacle providing 200-240V AC utility power.
3
External Battery Connector: Use this to connect one or more Tripp Lite battery modules to the power module. Remove the
4
cover for access. The power module will not start without a connection to a charged battery module. Refer to the battery
module Owner's Manual for connection instructions and safety warnings.
Maintenance Bypass Switch: This switch allows qualified service personnel to remove the detachable PDU from the power/
5
battery module for routine maintenance without disrupting power to connected loads. While this switch is set to BYPASS,
connected equipment will receive filtered AC mains power, but the equipment will not receive battery power in the event of a
blackout. See"Manual Bypass Operation" section for complete bypass procedure.
L6-30R AC Output Receptacles: Accept direct plug-in connection of NEMA L6-30 equipment plugs.
6
20A Output Breaker: One double-pole circuit breaker controls output power from the receptacles indicated on each model.
7
L6-20R AC Output Receptacles: Accept direct plug-in connection of NEMA L6-20 equipment plugs.
8
RS-232 Communication Port: This female DB9 serial port may be used to connect your UPS to a workstation or server. It
9
uses RS-232 protocol to communicate with a connected computer. It is used with Tripp Lite software and the included serial
cable to monitor and manage the UPS remotely over a network and to automatically save open files and shut down equipment
during a blackout. See"Optional Connection"section for details.
Mini-Slot: USB connector (disabled by default—DIP switches in the RS-232 position; to enable, move both DIP switches to
10
the USB position). An optional Contact-Closure card is available if needed (Tripp Lite part # RELAYIOMINI).
Parallel Connector: For UPS communication in parallel (functional only on the 6kVA model). Refer to the manual provided
11
with the Parallel PDU Kit. For more information, visit www.tripplite.com/support.
EPO (Emergency Power Off) Port: The power module features an EPO port that may be used to connect the power module
12
to a contact closure switch to enable emergency power off. See "Optional Connection" section for details.
Accessory Slot: Remove the small cover panel to install optional accessories to remotely control and monitor your UPS
13
system. Visit Tripp Lite on the Web (www.tripplite.com) to learn about available SNMP , network management and connectivity
products that may be installed in this slot.
Transformer AC Input/Output Terminal Block (6kVA UPS only): Use this terminal for interfacing an approved PDU system.
14
Utility Input Terminal Block (6kVA UPS and 12kVA IEC/PARALLEL/HARDWIRE module only): Use these terminals to
15
connect your power module to utility power. Unscrew and remove the cover over the block for access.
Equipment Output Terminal Block (6kVA UPS and 12kVA IEC/PARALLEL/HARDWIRE module only): Use these terminals
16
to connect your power module to your equipment. Unscrew and remove the cover over the block for access.
AC Input Breaker: One double-pole cicuit breaker controls input power to the power module.
17
Parallel Power Interconnect: For use with secondary parallel PDU only.
18
Maintenance Breaker (12kVA UPS only): Controls maintenance to the UPS.
19
AC Output Breaker: One double-pole circuit breaker provides Bypass for the parallel system to the load.
20
AC Output Receptacles (6kVA UPS/ IEC PDU Module only): Accept direct plug-in connection of IEC-320-C20
21
equipment plugs.
Secondary UPS Module
22
Secondary PDU Module
23
5-15/20R AC Output Receptacles: Accept direct plug-in connection of NEMA 5-15P or 5-20P equipment plugs.
24
Isolation Step Down Transformer: This self-contained unit provides a means to connect both low-voltage and high-voltage
25
devices to the UPS system.
Ground Screw: Use this to connect any equipment that requires a chassis ground.
26
(continued)
8