2. Parts Names
Display
The main display can be displayed in two different modes: "Full" and "Basic". The factory setting is "Full". To switch to the "Basic" mode, change the
setting on the Main display setting. (Refer to operation manual included with remote controller.)
<Full mode>
* All icons are displayed for explanation.
⑫ ⑬ ⑭ ⑮ ⑯
▌ ① Operation mode
Indoor unit operation mode appears here.
▌ ② Preset temperature
Preset temperature appears here.
▌ ③ Clock (See the Installation Manual.)
Current time appears here.
▌ ④ Fan speed
Fan speed setting appears here.
▌ ⑤ Button function guide
Functions of the corresponding buttons appear here.
▌ ⑥
Appears when the ON/OFF operation is centrally controlled.
▌ ⑦
Appears when the operation mode is centrally controlled.
▌ ⑧
Appears when the preset temperature is centrally controlled.
▌ ⑨
Appears when the filter reset function is centrally controlled.
▌ ⑩
Indicates when filter needs maintenance.
▌ ⑪ Room temperature (See the Installation Manual.)
Current room temperature appears here.
▌ ⑫
Appears when the buttons are locked.
▌ ⑬
Appears when the On/Off timer, Night setback, or Auto-off timer
function is enabled.
appears when the timer is disabled by the centralized control
system.
Most settings (except ON/OFF, mode, fan speed, temperature) can be made from the Menu screen.
(Refer to operation manual included with remote controller.)
⑰ ⑱
<Basic mode>
▌ ⑭
Appears when the Weekly timer is enabled.
▌ ⑮
Appears while the units are operated in the energy-save mode. (Will
not appear on some models of indoor units)
▌ ⑯
Appears while the outdoor units are operated in the silent mode.
▌ ⑰
Appears when the built-in thermistor on the remote controller is
activated to monitor the room temperature ( ⑪ ).
appears when the thermistor on the indoor unit is activated to
monitor the room temperature.
▌ ⑱
Indicates the vane setting.
▌ ⑲
Indicates the louver setting.
▌ ⑳
Indicates the ventilation setting.
▌ ㉑
Appears when the preset temperature range is restricted.
▌ ㉒
Appears when an energy-saving operation is performed using a "3D
i-See sensor" function.
▌ ㉓ Centrally controlled
Appears for a certain period of time when a centrally-controlled item is
operated.
▌ ㉔ Error display
An error code appears during the error.
* When an error code is displayed on the main display, an error is
occurring but the indoor unit can keep its operation. Check the error
code, and consult your dealer.
5