Télécharger Imprimer la page

Invicta ELO S Notice Particulière D'utilisation Et D'installation page 19

Publicité

Les langues disponibles

Les langues disponibles

ELO S Wood Stove
Reference : 6102 14 vers.1.1
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is
an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke
control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt"
appliance ("exempted" from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20
and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are exempted by
publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In Northern Ireland
appliances are exempted by publication on a list by the Department of Agriculture, Environment and Rural Affairs under Section 16
of the Environmental Better regulation Act (Northern Ireland) 2016.
In Wales appliances are exempted by regulations made by Welsh Ministers.
Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control
areas and you can contact them for details of Clean Air Act requirements"
The ELO S stove has been recommended as suitable for use in smoke control areas when burning wood logs and when fitted with a
modified air control to prevent closure of the secondary air .
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling must
be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling to prevent excessive smoke
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open except as
directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated with air
controls, appliance dampers or door left open excepas directed in the instructions.
Page 19 sur 20
XD, le 07/01/2019

Publicité

loading

Ce manuel est également adapté pour:

6102 14