Figure 11
5. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent,
such as dishwashing liquid, and dry with a soft cloth. NEVER
USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions
in Section 6 Finishing the Installation , to reinstall grill.
2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth
or gently vacuum the fan. NEVER IMMERSE ELECTRICAL
PARTS IN WATER.
Trouble
1. Fan does not operate when the switch is on.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal.
210952012 Rev. B 8-06
CAUTION:
3. Changing the Light Bulb: Disconnect power to the unit.
Troubleshooting Guide
Probable Cause
1a. A fuse may be blown or a circuit tripped.
1b. Connector plug from motor is not plugged in.
1c. Wiring is not connected properly.
2. Obstruction in the exhaust ducting.
3a. Motor is loose.
3b. Fan blade is hitting housing of unit.
www.airkinglimited.com
https://manual-hub.com/
ALLOW BULBS TO COOL BEFORE REPLACING.
Remove grill by pulling downward on grill and squeezing grill
springs together to release from housing (Figure 12).
Incandescent Bulb (AK100L): Unscrew bulb from lamp
holder and replace with a 100 watt maximum, type A19
medium base incandescent bulb.
Fluorescent Bulb (AK100FL): Remove lamp by gently
rocking lamp back and forth while applying outward
pressure to release the lamp from the base. Replace
with a 26 watt maximum, 2 pin quad, fluorescent lamp.
Night Light (AK100L, AK100FL): Unscrew night light bulb
from socket and replace with a 7 watt maximum type C7
(candelabra base) night light bulb.
Refer to instructions in Section 6 Finishing the Installation ,
to reinstall grill.
Figure 12
Suggested Remedy
1a. Replace fuse or reset circuit breaker.
1b. Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c. Turn off power to unit. Check that all wires are connected.
2. Check for any obstructions in the ducting. The most common are bird nests
in the roof cap or wall cap where the fan exhausts to the outside.
3a. Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b. Call your dealer for service.
4 of 12