IMPORTANT INSTRUCTIONS -
Models:
AKLC701, AKLC702,
AKLC703, AKLC709
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
210572200 Rev. B 1-13
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING:
STALL ENCLOSURE.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
CAUTION:
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
WARNING:
g) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan with Light
DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
DO NOT USE IN KITCHENS.
1 of 12

Publicité

loading

Sommaire des Matières pour Air King AKLC701

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AKLC701, AKLC702, Exhaust Fan with Light AKLC703, AKLC709 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill with Glass Light Lens 1 - Damper Assembly (attached) Figure 3...
  • Page 3 receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 10). Use approved methods for all connections. Supply Ground (Green or Bare) from house Wire Neutral (White) Compartment Screw Hot (Black) Cover Figure 6 1b.
  • Page 4 SECTION 7 CAUTION: FAILURE TO SECURE THE GRILL MAY RESULT IN A RATTLING OR HUMMING NOISE. Use and Care Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included). CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.
  • Page 5 WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6 REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Qty. Description Replacement Part # Mounting Rails 5S1299002 Polarized Receptacle 5S1999001 External Wire Cover 5S2299014 Blower Assembly 5S2234007 Collar/Damper 5S1299111 Light Assembly - Bronze 5S5231001 Gasket - Collar 5S2299015 Light Assembly - Nickel 5S5231002 Interior Wire Cover 5S2234001...
  • Page 7 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : AKLC701, AKLC702, Exhaust Fan with Light AKLC703, AKLC709 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir: 1 - Grille avec les Lentilles de l’éclairage 1 - Ensemble de clapet (attaché) 2 - Vis #8...
  • Page 9 du commutateur mural aux deux fils rouge du réceptacle de la lumière et au fil noir du réceptacle du ventilateur d’évacuation. Raccorder le fil de mise à la terre de la maison au fil vert de la vis de mise à la terre du ventilateur (Figure 10). Utiliser des méthodes de raccordement approuvées pour toutes les connexions.
  • Page 10 SECTION 7 AVERTISSEMENT: UN MANQUEMENT A BIEN SERRER LES VIS DU REFLECTEUR PEUT RESULTER EN UN BRUIT DE CRECELLEMENT OU DE GRONDEMENT. Utilisation et entretien Installer 2 ampoules incandescentes à culot moyen de type A19 de 60 watts au maximum AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE (non-comprises).
  • Page 11 QUE FERA AIR KING : Au cours de la période de garantie, Air King, à son choix, réparera ou remplacera n’importe quelle partie ou pièces qui s’avèrent défectueuses ou remplacera le produit entier par le même modèle ou un modèle comparable.
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce # de pièce Qte Description de remplacement Qte Description de remplacement Traverses de montage 5S1299002 Polarized réceptacle 5S1999001 Couvercle de câble externe 5S2299014 Assemblée de la soufflante 5S2234007 Collet / clapet 5S1299111 Assemblée de la lumière - Bronze 5S5231001 Joint –...