IMPORTANT INSTRUCTIONS -
Models: AIK14X, AIK16X, AIK24Y, AIK26Y,
AIF4X, AIF6Y, AIF8X, AIF10X,
AIG4, AIG6
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
WARNING:
DO NOT CONNECT POWER SUPPLY UNTIL FAN
IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
TO THE FAN IS LOCKED IN OFF POSITION.
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
5S7635036 New 9-06
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
9. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
10. Suitable for use with solid-state speed control.
11. This unit has rotating parts and safety precautions should be
exercised during installation, operation and maintenance.
12. Guards must be installed when fan is within reach of personnel
or within seven (7) feet of working level or when deemed
advisable for safety.
13. NEVER place a switch where it can be reached from a tub or
shower.
14. Do not insert or allow fingers or foreign objects to enter the
motor.
WARNING:
www.airkinglimited.com
In-Line Exhaust Fan
DO NOT USE IN KITCHENS
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour Air King AIF10X

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AIK14X, AIK16X, AIK24Y, AIK26Y, In-Line Exhaust Fan AIF4X, AIF6Y, AIF8X, AIF10X, AIG4, AIG6 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing for Fan Installation 1. When selecting fan mounting location, the following criteria Stud should be considered: a) Mounting to minimize noise generated by fan operation: Mounting the fan as far as possible from the intake point will minimize fan operating noise from being Screws...
  • Page 3 SECTION 6 Joist/Stud Joist/Stud Ducting Collar/Damper CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. NOTE: Insulated ducting is required for bathroom exhaust Screws applications, where ducting passes through unconditioned space Collar/Damper or where noise is a factor. Failure to use insulation could result in excessive condensation buildup within the duct, and Wall/Ceiling Material Figure 4...
  • Page 4 NOTE: When using insulated flex duct, it is recommended that the inner vinyl core be screw clamped or taped to the inlet and outlet and that the vapor barrier surrounding the insulation be taped to the fan housing. Screws NOTE: When attaching flex duct to the collar/damper combination and an immediate elbow is necessary, be certain that the elbow is installed with a "soft"...
  • Page 5: Troubleshooting Guide

    Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 6: Replacement Parts Diagram

    Cover Plate - AIF4X 5S7635029 Grill - AIG6 5S7635017 Cover Plate - AIF6X 5S7635030 Grill Spring 5S7635028 Cover Plate - AIF8X, AIF10X 5S7635031 Screw - AIF4X 5S7699021 Screw - AIF6X, AIF8X, AIF10X 5S7699023 Mounting Bracket - AIF4X, AIF6X 5S7635035 Mounting Bracket - AIF8X, AIF10X...
  • Page 7 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: AIK14X, AIK16X, AIK24Y, AIK26Y, Ventilateur d’évacuation AIF4X, AIF6Y, AIF8X, AIF10X, en série AIG4, AIG6 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 INSTRUCTIONS D’INSTALLATION Montant AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER Ventilateur L’INSTALLATION. SECTION 1 Préparation en prévision de l’installation du ventilateur 1. Lorsque vous choisissez l’emplacement pour l’installation du ventilateur, les critères suivants doivent être pris en compte : a) Installation visant à...
  • Page 9: Ventilateur

    REMARQUE : Un conduit isolé est requis pour les installations Montant / Solive Montant / Solive d’évacuations de salles de bain, lorsque le conduit passe par un emplacement non climatisé ou dans un emplacement où le bruit Collet / clapet représente un facteur important.
  • Page 10 REMARQUE : Lorsqu’un conduit isolé flexible est utilisé, il est recommandé de fixer l’âme de vinyle interne du trou d’entrée et de sortie à l’aide d’une vis de serrage ou de ruban adhésif et que le pare-vapeur entourant le revêtement isolant soit fixé à l’aide de ruban adhésif au châssis du ventilateur.
  • Page 11: Cause Possible

    GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 12: Diagramme Des Pièces De Remplacement

    Plaque de finition - AIF4X 5S7635029 Grille - AIG4 5S7635016 Plaque de finition - AIF6X 5S7635030 Grille - AIG6 5S7635017 Plaque de finition - AIF8X, AIF10X 5S7635031 Ressorts pour la grille 5S7635028 Vis - AIF4X 5S7699021 Vis - AIF6X, AIF8X, AIF10X 5S7699023...

Ce manuel est également adapté pour:

Aik14xAik16xAik24yAik26yAif4xAif6y ... Afficher tout

Table des Matières