Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
:
Models
AK100L, AK100FL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
SAVE THESE INSTRUCTIONS
210952012 Rev. B 8-06
GENERAL SAFETY INFORMATION
www.airkinglimited.com
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
DO NOT USE IN KITCHENS
https://manual-hub.com/
Exhaust Fan with Light
1 of 12

Publicité

loading

Sommaire des Matières pour Air King AK100FL

  • Page 1 OPERATING MANUAL Models Exhaust Fan with Light AK100L, AK100FL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: Joist 1 - Grill Figure 3...
  • Page 3 Connect one hot (black) wire from the wall switch to the black wire from the fan (this is the fan control). AK100FL: 26 watt maximum, 2 pin quad, fluorescent lamp Connect second hot (red) wire from the wall switch to the red (not included) and a 7 watt maximum type C7 (candelabra wire from the fan (this is the night light control).
  • Page 4 Replace Figure 11 with a 26 watt maximum, 2 pin quad, fluorescent lamp. Night Light (AK100L, AK100FL): Unscrew night light bulb 5. Restore power and test your installation. from socket and replace with a 7 watt maximum type C7 (candelabra base) night light bulb.
  • Page 5 Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 6 Motor Plate 5S1202011 #10 Ground Screw 5S1999002 Hex Nut 5S1202012 Wire Cover & Light Harness 5S1202022 Blower Wheel 5S1202013 FL Lamp Holder - AK100FL* 5S1202025 Venturi 5S1202014 Ballast - AK100FL* 5S1202026 Screw 5S1999011 Screw - AK100FL* 5S1202027 Light Reflector - AK100L...
  • Page 7 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur combiner, comprend Modéles AK100L, AK100FL lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 INSTRUCTIONS D’INSTALLATION dissimulés ou autres utilités. Installer les traverses sur le châssis et positionner le châssis dans le trou percé AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION précédemment afin qu’il soit à effleurement avec le plafond EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER fini.
  • Page 9 (celui-ci est pour le contrôle de la lumière principale). Raccorder le fil de mise à la terre de la maison au AK100FL: Installer une ampoule fluorescente d’un fil vert du ventilateur (Figure 8). Utiliser des méthodes de maximum de 26 watts, quad à 2 tiges (non-comprise) et raccordement approuvées pour toutes les connexions.
  • Page 10 Remplacer l’ampoule avec une ampoule fluorescente d’un maximum de 26 watts, quad à 2 tiges. Lumière de Nuit (AK100L, AK100FL): Dévisser l’ampoule de lumière de nuit de son socle et la remplacer avec une ampoule de lumière de nuit de type C7 d’un maximum de 7 watts (culot de type candélabre).
  • Page 11 GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 12 Qty. Description de remplacement Qty. Description de remplacement Cabinet du ventilateur 5S1202008 Harnais de la Lampe - AK100L 5S1202016 Traverses de Montage 5S1299002 Harnais de la Lampe - AK100FL 5S1202024 Couvercle de Câble Externe 5S1202007 Clip 5S1202017 5S1999010 Bague 5S1202018 Collet...

Ce manuel est également adapté pour:

Ak100l