MANUAL OPERATION
Operation of the heater is under the direct control of the user. Heat output will, however, be automatically adjusted
in accordance with the room temperature registered by the temperature sensor.
1. Turning Heater ON
A. Press ON/OFF button to "ON" position.
The current room temperature and
the set temperature will be shown on
the Display. If the room temperature
is below the set temperature then.
ON lamp will start to flash and then
blower motor and ignition will start. This lamp will continue to flash during the preheating time.
B. Pre -heating depends on the room temperature. After approx. 1.5 – 4 minutes ignition will take place. (*) After
ignition, ON lamp will change flashing to continuous. Circulation fan will turn on after approx. 2 minutes.
NOTE: (*) Pre -heating depends on the room temperature.
Room temperature:
below 0˚C
0˚C - 15˚C
15˚C Over
2. Adjusting Room Temperature
A. Press "sMIN." or "tHOUR" button. ˚F
or ˚C will start to flash.
NOTE: "sMIN." or "tHOUR" button
will change the temperature in
increment of 1°C (2°F).
B. Press "sMIN." for up and "tHOUR" for down. Room temperature can be set from 10˚C (50˚F) to 32C (90˚F).
(Initial setting : 13˚C (56˚F))
C. When room temperature reaches the selected setting, heater will automatically shift to "MED" or "LOW"
burning mode to maintain the desired temperature.
When room temperature exceeds the selected setting by approx. 2˚C (4˚F), the heater will automatically shut
off. As room temperature drops, the heater will automatically re-start to maintain the desired temperature.
POWER SAVER OPERATION
The Power Saver mode reduces the frequency
of ignition actions, to save electric consumption.
1. Press the POWER SAVER (CHILD LOCK)
button "ON" while in operation to start the
operation of the "POWER SAVER". "POWER
SAVER" sign will be shown on the display.
When the room temperature exceeds the selected setting by approximately 6˚C (12˚F), the heater will automatically
shut off. As the room temperature becomes lower than the selected setting, the heater will automatically re-start
to maintain the desired temperature.
FF-55T_FF-55_Type E_6 language_A4.indb
9
OPERATION
Approx. 4 minutes
Approx. 2 minutes
Approx. 1.5 minutes
ENGLISH
GB
9
2023/06/21