Installation
(for the qualified professional)
Unpacking
Inspect the new appliance for transport damage!
Please dispose of the packaging, and if applicable, the old
appliance in an environmentally-friendly manner.
Install the small water heater as shown in the illustra-
tions. Observe the instructions in the text.
The illustrations can be found in the centre of the instruction
manual.
A
Scope of delivery/Dimensions
Undersink appliance DO10702
Water connection
B
Caution!
Do not allow the existing tap mixer to become calcified.
A reduced flow rate will ruin the water heater.
Wall mounting
C
For mounting without the wall hooks, observe the differ-
ent dimensions!
D
Screwing on the Connection Hoses
Fit the sealing gasket.
Place the sleeve nuts onto the threads and screw on by
hand.
Tighten the screw fitting.
Hold the threaded fittings on the water heater with a
spanner. Do not lubricate the thread!
After the unit has been used to heat water a few times,
retighten the screw fitting.
Replacement for a damaged threaded fitting is available from
customer service.
Oversink appliance DO10802
Wall mounting
E
For mounting without the wall hooks, observe the differ-
ent dimensions!
F
Connecting the tap mixer
8
en
Water connection
G
Caution!
Do not allow the existing tap mixer to become calcified.
A reduced flow rate will ruin the water heater.
Insert the connection pipes into the tap mixer.
Hang the water heater on the wall.
Screw the connection pipes onto the heater and the
tap mixer.
Hold the threaded fittings on the heater with a spanner.
Do not lubricate the thread!

First start-up

H
Electrical connection
Important: Do not insert the plug into the mains socket yet.
DO10702 only:
Open the corner valve.
Completely fill the heater's reservoir with water.
Set the flow on the corner valve:
10-litre unit: 10 l/min = 1 l in 6 seconds
DO10802 only:
Set the flow with the adjustment screw on the tap mixer:
10-litre unit: 10 l/min = 1 l in 6 seconds
Only then insert the plug into the mains socket.
Checking the heating
Turn the rotary selector switch to "III" (approx. 85 °C).
Monitor the heating process until the pilot lamp
switches off.
Heating time:
10-litre unit: 25–35 minutes
Check the temperature.
Caution: If the safety temperature limitation has switched
off the small water heater, unplug the mains plug, open
the warm water tap and allow approx. 4 litres of water to
flow. Then plug the mains plug back in.
The appliance is ready again for operation.
Limitation of the water temperature
The temperature of the water leaving the tap for the small
water heater can be mechanically set to stage "I" (approx.
40 °C) or stage "e" (approx. 60 °C).
Information on temperature limiting can be found in the
operating instructions.
Saving energy
Turn the rotary selector switch to "e".
Hand over the installation and operating instructions to
the user and explain how the appliance operates.