Télécharger Imprimer la page

Eaton Xenon beacon XB8 Document Technique page 6

Publicité

Les langues disponibles

Les langues disponibles

Xenon beacon - XB8
English
3.0 Operation
The operating voltage of the unit is stated on the unit label.
The beacon can be initiated directly when power is applied, if the local link between terminals 7 and 8 is connected.
Alternatively, the local link can be removed and a remote, voltage free contact can be connected to terminals 7 an d 8 in its
place. In this case, the beacon will only flash when power is connected to the terminals and the remote contact is closed.
General arrangement
107±2mm
Ø140±2mm
50±1mm
Barrier types
Typical suitable barrier types are shown in the table below
Xb8 unit type
12VIIB/IIC
24V IIC
24V IIB
Installation drawing
NON-HAZARDOUS AREA
UNSPECIFIED EXCEPT THAT IT
MUST NOT BE SUPPLIED FROM
NOR CONTAIN UNDER NORMAL
OR ABNORMAL CONDITIONS A
SOURCE OF POTENTIAL WITH
RESPECT TO EARTH IN EXCESS
OF 250V R.M.S. OR 250V D.C.
2
Xenon beacon - Xb8 TM126 Issue G February 2024 www.eaton.com
FIXING HOLES
Ø6.5±1MM
2 POSITIONS
20±1mm
40±1mm
40±1mm
barrier/galvanic isolator
specification
15V, 291mA
28V, 119mA
25V,147mA
25v,83.3mA
25v,83.3mA
28V, 170mA
25v,166mA
NON-HAZARDOUS AREA
1
2
ONE SHUNT
ZENER DIODE
SAFETY BARRIER
Typical safety device
MTL7715P+
MTL 7728P+
MTL4521
MTL4525
MTL 5525
MTL 7729P+
MTL 5522
HAZARDOUS AREA
3
4
BEACON TYPE
XB8
Ex ia IIB/IIC T4
(Tamb -55 C TO + 60 C)
Safety device cert no
BAS01ATEX7218
BAS01ATEX7217
Baseefa06ATEX0155
Baseefa06ATEX0155
Baseefa07ATEX0212
BAS01ATEX7218
Baseefa07ATEX0212

Publicité

loading