Télécharger Imprimer la page

BWT VI-HC 135 Mode D'emploi page 13

Publicité

Les langues disponibles

Les langues disponibles

FOR INSTALLERS AND PROFESSIONALS
1.1. When storing or moving the heat pump, the heat pump should be at the upright
position. Otherwise the machine couldn't work.
1.2. When moving the heat pump,do not catch the water union to avoid the titanium
heat exchanger damage.
The heat pump must be installed by a professional team. The users are not qualified to install by
themselves, otherwise the heat pump might be damaged and risky for users' safety.
2.1.Notice before installation:
2.1.1. The inlet and outlet water unions can't bear the weight of soft pipes. The heat pump must be
connected with hard pipes!
2.1.2.In order to guarantee the heating efficiency, the water pipe length should be ≤10m between
the pool and the heat pump.
1. TRANSPORTATION
2. INSTALLATION AND MAINTENANCE
2019/11– C - Code : 33240
13 /76

Publicité

loading

Ce manuel est également adapté pour:

Vi-hc 175Vi-hc 210