Télécharger Imprimer la page

AYA AFE55B Instructions D'utilisation page 70

Publicité

Les langues disponibles

Les langues disponibles

To connect the oven power cord, loosen and remove the cover on
o
the terminal block, in order to gain access to the contacts inside.
Make the connection, securing the cord in place with the cable
clamp provided and then immediately close the terminal block
cover again.
If you have to change the oven power cord, the earthing
o
(yellow/green) conductor must always be 10 mm longer than the
line conductors.
Care must be taken to ensure that the temperature of the mains
o
supply cable does not exceed 50°C.
If the mains supply cable is damaged, then it must be replaced by
o
an appropriate replacement which can be obtained from Spares
Department.
INSTALLATION NOTES
1.
The oven has to be installed as indicated in Fig.4, Whether under a hob
or in a column.
2.
On inserting the oven in a column, it is essential in order to ensu re there
is enough ventilation, to rem ove the rear pa nel of the fur niture and
have an opening of at least 85 – 90 mm as indicated in Fig.4.
3.
Check that the oven has been fixed securely in the housing. Fixing the
oven into the cupboard is done using 4 screws. One in each corner of
the oven door frame.
EN-31