Switching on the unit
N O T E
Ensure that the pump never runs dry!
The pump will be destroyed.
• Regularly check the water level and circulation in
the filter and in the aquarium.
N O T E
Risk of fire due to the hot surface of the heater!
The heater and filter can be destroyed by the gener-
ated heat.
• Do not switch the heater on until the filter is com-
pletely filled with water, switched on and the water
is continuously circulated.
• Switch off the heater and allow it to cool down be-
fore removing it from the water.
How to proceed:
R
1. Route each power connection cable such that it
forms a drip loop.
2. Connect the power connection cable to the power
supply.
– The pump will switch on immediately.
– Trapped air in the filter can cause noise. The
trapped air escapes shortly after the pump starts
up.
3. Unit with heater: Set the water temperature on the
heater and switch on the heater. (→ Heater opera-
ting manual).
Switching off the unit
How to proceed:
• Disconnect the unit from the power supply
• Unit with heater: Disconnect the unit and heater
from the power supply
Setting the flow rate
How to proceed:
S
• Move the lever on the connection unit to set the de-
sired flow rate
– "LOCK": Maximum flow rate
– "UNLOCK": No flow, the outlet is closed.
24
MAINTENANCE AND CLEANING
• If necessary, clean with clear water using a soft
brush.
• Do not use cleaning agents or chemical solutions.
We recommend using OASE PumpClean for remov-
ing calcium deposits.
• Cleaning and replacement cycles for filter media are
dependent on the size of the aquarium and the
number of fish. Therefore, it is necessary to clean
and replace the filter media as required to ensure
optimum filter performance.
• If there are several foam filters: Clean or replace the
foam filters at different times. This saves enough
useful bacteria to ensure good biological filtration
of the water.
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to remove
any soiling. (→ Cleaning/replacing the filter media)
Cleaning and maintenance work:
Area
Tasks to be carried out
Foam filter, pre-filter (→ Cleaning/replacing the foam fil-
ter of the pre-filter)
Filter media, contai-
(→ Cleaning/replacing the filter me-
ner
dia)
Heater
Impeller unit, pump
(→ Cleaning/replacing the impeller
casing
unit)
Valve box, pre-filter
(→ Cleaning the valve box of the
pre-filter)
Suction chamber,
(→ Cleaning the suction chamber of
pre-filter
the pre-filter)
N O T E
The cycle for cleaning the foam filter in the pre-filter is
longer if a coarser foam filter is used.
BioMaster, BioMaster Thermo
HeatUp 25/50/75/