VISIOMED TensioFLASH KD-798 Manuel D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTROMAGNETIC COMPATIBILITY INFORMATION
Table 1
For all ME EQUIPMENT and ME SYSTEMS
Guidance and manufacture's declaration - electromagnetic emissions
The KD-738 is intended for use in the electromagnetic environment specified below.
The customer or the user of the KD-798 should assure that it is used in such an environment.
Emissions test
Compliance
RF emissions
Group 1
CISPR 11
RF emissions
Class B
CISPR 11
Harmonic emissions
Not applicable
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
Not applicable
IEC 61000-3-3
34
Visiomed - KD-798 - Manuel d'utilisation - 0720176
Electromagnetic environment - guidance
The KD-798 uses RF energy only for its internal
function. Therefore, its RF emissions are very low
and are not likely to cause any interference in
nearby electronic equipment.
The KD-798 is suitable for use in all esta-blish-
ments other than domestic and those directly
connected to the public low-voltage power
supply network that supplies buildings used for
domestic purposes.
Table 2
For all ME EQUIPMENT and ME SYSTEMS
Guidance and manufacturer's declaration - electromagnetic immunity
The KD-798 is intended for use in the electromagnetic environment specified below. The customer or the user of the
KD-798 should assure that it is used in such an environment.
IEC 60601test
IMMUNITY test
Compliance level
level
Electrostatic discharge
± 6 kV
± 6 kV contact
(ESD)
contact
± 8 kV air
IEC 61000-4-2
± 8 kV air
Power frequency
(50/60 Hz)
3 A/m
3 A/m
magnetic field
IEC 61000-4-8
Table 3
For all ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING
Guidance and manufacturer's declaration - electromagnetic immunity
The KD-798 is intended for use in the electromagnetic environment specified below. The customer or the user of the
KD-798 should assure that it is used in such an environment.
IEC
IMMUNITY test
60601test
level
RADIATED RF IEC 61000-4-3
3V/m 80
MHz to
2.5 GHz
Visiomed - KD-798 - Manuel d'utilisation - 072017
Electromagnetic environment - guidance
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical com-
mercial or hospital environment.
Compliance
Electromagnetic environment - guidance
level
3 V/m
Portable and mobile RF communications
equipment should be used no closer to any
part of the KD-798, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
35

Publicité

Chapitres

Table des Matières
loading