Specification And Performance Data Sheet - Gaggenau RY 492 Notice D'utilisation

Masquer les pouces Voir aussi pour RY 492:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specification and performance
data sheet
For filter model: 9000 077 095
Using replacement car tridge: 9000 077 104
The model was tested by NSF International with
reference to ANSI/NSF Standards 42 & 53
and certified for a reduction in the substances cited
below.
Substance Average in
inflow
Cysts *
166,500
Turbidity
10.7
Particle
5,700,000
class 1
particle
size > 0.5 t
o < 1.0 μm
Taste
1.9
of chlorine
and turbid-
ity
* Based on the use of Cryptosporium parvum ocysts.
Application guidelines / Water supply parameters::
Water pressure
Water temperature *
Flow rate
The system is to be installed and operated
according to the guidelines recommended by
the manufacturer.
The filter is to be changed every 6-9 months.
Rinse new filter thoroughly for 5 minutes.
More detailed information can be found on
the warranty card.
Inflow concen-
Waste water
tration
concentration
Min. 50,000/l
1
11 x 1 NTU
0.3 l
At least 10,000
30.583
particles/ml
2.0 mg/l + -
0.05
10%
30 - 120 psi
(207 - 827 kPa)
33 °F - 100 °F
(0.6 °C - 38 °C)
0.75 gpm (2.83 l/min.)
The concentration of the indicated substances which
are dissolved in water and penetrate the system was
reduced to a value below or equal to the permitted
limit value in accordance with NSF/ANSI 42
and 53 for water discharged out of the appliance.
Note:
Even though the tests were conducted under standard
laboratory conditions, the actual performance may
deviate from these tests.
The system was tested and certified on model
9000 077 095 by NSF International with refer-
ence to ANSI/NSF Standard 53 for a reduction in
cysts and turbidity, as well as with reference
to ANSI/NSF Standard 42 for a reduction in
the taste and odour of chlorine.
Nominal particle class: I
Nominal service life: 739.68 gallons (2,800 litres)
Average reduc-
Max. permitted
tion as %
concentration in
waste water
99.99
99.95
97.10
0.5 NTU
99.52
> 85%
97.3
> 50%
Without appropriate disinfection before and af ter
connecting it to the system, this product should
NOT be used if the water is microbiologically
contaminated or if the quality has not been
ascertained. A system certified for cyst reduction
should be used for disinfected water which possibly
contains filterable cysts.
A one-year warranty is issued for the entire system
(except disposable cartridge). With reference
to disposable cartridges a warranty is issued for
material and processing faults only. As the service life
of disposable cartridges depends on the local water
conditions, no warranty is issued for them.
More detailed information on the prices of spare parts
is available from your appliance dealer or parts
salesman on site.
Manufactured by :
Cuno Engineered Products
1000 Apollo Road
Eagan, MN 55121-2240 U.S.A.
Max. waste
Min. reduc-
water
tion as %
1
99.99
0.49
95.42
69.000
98.9
0.06
96.84
NSF test
511077-
03
511078-
03
511079-
03
511081-
03
17