JUNIOR 624
ELECTRICAL CONNECTIONS TO THE TERMINALS AND THEIR FUNCTIONS
Accessory
Connections for n° 2
Junior 624 sliding gate
operators
2
1
Master
Slave
n° 4x1
Output for courtesy
lamp relay
max 24 Vdc - 50 mA
Pedestrian input
NC contact for
nd
2
Junior input
ELPRO 64
Electrical connections
It is important to determine which Elpro 64
!
MASTER will command and control the Elpro 64
SLAVE. All the accessories for command,
signalling and safety must be connected to the
terminals of the Elpro 64 MASTER that manages
and controls the entire system. If the gates aren't
of the same length, the Elpro 64 MASTER is to be
mounted on the longest one.
Carry out the following connections:
Elpro 64 SLAVE
Elpro 64 MASTER
dip-switch 12 = ON:
dip-switch 12 = OFF:
terminal 15 (open)
terminal 4 (open)
terminal 5 (close)
terminal 16 (close)
terminal 3 (common)
terminal 17-23 (common)
terminal 22
terminal 16 (close)
terminal 17 jumper with 23
terminal 1 jumper with 2
terminal 3 (common) jumper with
Master
15 16 17
20 21 22 23 24
23
17
A 4-wire cable is necessary for the connection
between the two Elpro 64 programmers
Output for courtesy lamp relay
18 19
max 24 Vdc - 50 mA
20
23
NO input for external contact for
pedestrian opening
22
23
Pre-fitted jumper. NC contact for
connection to 2
Dip-switches and LED indication of their functions
DIP-SWITCH 12
12
6 (stop)
1 2 3 4 5 6
3
PROGRAMME JUNIOR MASTER AND SLAVE
!
SEPARATELY
CONNECTIONS HAVE BEEN MADE AND THE
DIP-SWITCHES SET CORRECTLY
nd
Junior
29
nd
ON: Elpro 64 SLAVE (2
Junior 624)
OFF: Elpro 64 MASTER (1
st
Junior 624)
Refer to the previous pages for the
!
dip-switch arrangements relative to the
individual accessories and functions.
L21, L22, L24 green = ON
with both programmers to confirm proper
communication between the two Elpro 64s
Slave
15
16 17
20 21 22 23 24
ONCE
THE
ELECTRICAL
Pedestrian trimmer: the opening
distance of the gate is adjusted up to
3 metres.
In Automatic function (dip 3 = ON,
closes after pause time completed)