JUNIOR 624
FASTENING THE LIMIT SWITCH BRACKETS TO THE GEAR RACK
ATTENTION: do not open and invert the single magnets inside the limit switch plastic brackets.
!
These have already been properly installed to be identified by programmer logic.
NOTE WELL: IT IS MOST IMPORTANT THAT THE GATE DOES NOT RUN INTO THE GATE STOPS IN OPENING AND CLOSING
!
CYCLES. A 30-50 mm CLEARANCE IS RECOMMENDED ON LIMIT SWITCH ENGAGING, AS INDICATED.
max 10 mm
!
30-50 mm
electro-mechanical sliding gate operator
SX left bracket
of the magnetic
limit switch
!
DX right bracket
of the magnetic
limit switch
25
!
30-50 mm
Pic. 11