JUNIOR 624
ANCHORING THE JUNIOR
1
ELECTRICAL POWER SUPPLY TO THE PROGRAMMER
!
ATTENTION: disconnect the 230 Vac
electrical power supply from the
system by the mains switch
NO
DISTINCTION OF JUNIOR INSTALLED ON THE RIGHT OR LEFT
The first operation to be performed is to identify the Junior installation with respect to the opening of the gate, moving dip-switch n° 11 on
the Elpro 64 programmer (already installed on the Junior 624), depending on the position of Junior as seen inside the gate to be opened
(Pic. 10).
opening direction
Junior installed to the LEFT:
position dip-switch n° 11 to OFF
OFF
electro-mechanical sliding gate operator
2
2
230 V V
!
2 mm
Terminal board for Junior
power supply
Junior installed to the RIGHT:
position dip-switch n° 11 to ON
24
3
opening direction
Pic. 8
Pic. 9
ON
Pic. 10