Auto stand by
The hob will automatically switch off if left (with pan) on for an extended period of time, see maximum
running times below
Appliance errors
Appliance
Errors
ER03 and
permanent tone
E2
E3
E/h
Power Level
1
2
3
4
5
6
7
8
9
P (Power Boost)
Fault Description
Continuous button actuation;
control switches off after 10
seconds
over temperature
1. Pot/pan not suitable, example
Loss of magnetic properties
because of temperature at
bottom of pot.
2. Power of cooking zones
permanently exceeded
Invariable resistor fault
Maximum Operation Time
hours
8
6
5
5
4
1.5
1.5
1.5
1.5
5 minutes
Clean the user interface.
Allow system to cool
1. This error is reset after 30 seconds; the
cooking zone can be used again. The pot/pan
must be removed if the fault keeps reoccur-
2. The power unit must be replaced if the er-
ror continues to be displayed even when no
pot/pan is present on the cooking zone.
Induction module must be cool
Action
ring.