Burner and nozzle specifications
Table 1
Burner
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Semi-Fish burner (SP)
Supply
pressures
*
A 15°C e 1013,25 mbar-dry gas
**
Propane
***
Butane
Natural
S
TC
PHN 932 T2/IX/A
12
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nominal
Reduced
100
2.60
0.70
75
1.65
0.40
55
1.00
0.40
130
3.25
1.50
-
1.50
0.70
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
3
P.C.S. = 37.78 MJ/m
S
TC
TC
SP
PHN 961 TS/IX/A
PHN 962 TS/IX/A
Liquid Gas
By-pass
Nozzle
Flow*
1/100
1/100
(mm)
(mm)
***
39
80
189
28
64
120
28
50
73
61
91
236
39
60
109
28-30
20
35
A
RR
Natural Gas
Nozzle
Flow*
g/h
1/100
l/h
(mm)
**
186
110 (Y)
248
118
96 (Z)
157
71
71 (X)
95
232
133 (Z)
309
107
88
143
37
20
25
17
45
25