Installation procedure

Cut the JRG Sanipex MT pipe (only d16 and d20,
JRG no. 4837) to the required length or with the
multi-purpose-cutter and pipe cutter
(JRG no. 4836).
I
52
After sliding over the plastic nut, the JRG
Sanipex MT pipe has to be pushed over the
mandrel until the mark, after that close
the clamping lever (4).
Remark
Correct expansion mandrel
Pay attention, that the expansion mandrel
(5) corresponding to the respective pipe as
well as the clamping jaws (2) corresponding
to the respective dimension are in place.