Télécharger Imprimer la page

VOLTCRAFT MSW 300 Serie Mode D'emploi page 45

Publicité

Les langues disponibles

Les langues disponibles

11. TROUBLESHOOTINg
Inverter cannot be switched on, "Power" LED is not lit.
• The rechargeable battery used for operation is flat. Connect the inverter to another, fully
charged rechargeable battery.
• The polarity was swapped at connection. Check the wiring.
• The cable connections with the rechargeable battery are not correct; e.g. the connection
cable is not screwed on. Tighten the screws of the terminal clamps.
• The fuse has tripped. Check the fuse and replace it if required.
The inverter works only with a consumer with a lower power consumption.
• The connection cable to the rechargeable battery is too long or the line cross-section is too
small. Replace the connection cable by a shorter one; use a cable with a larger line cross-
section.
• The consumer's power consumption is too high for the inverter.
• The consumer's power consumption is too high when starting up.
The connected consumer is not working and the "fault" LED is lit.
• The consumer's power consumption is too high for the inverter; overload protection has
been activated.
• The consumer's power consumption is too high when starting up; overload protection has
been activated.
an alarm sounds.
• Undervoltage recognition has been activated. The rechargeable battery that is used for
voltage/current supply of the inverter is flat. Connect the inverter to another, fully charged
rechargeable battery.
• The overtemperature protection has been activated. Switch the inverter off and let it cool off
sufficiently.
Check if the inverter is sufficiently ventilated.
Operate the inverter in a cooler environment.
Connect a consumer with lower power consumption.