Operation
the solar charge current, the controller will no longer be able to maintain the battery at
the Float setpoint. Should the battery voltage remains below the boost reconnect charging
voltage, the controller will exit Float stage and return to Bulk charge.
● Equalize Charge
Equalizing flooded battery can produce explosive gases, so ventilation of battery box is
necessary.
Equalization may increase battery voltage to a level that is damaging to sensitive DC loads.
Ensure that all load allowable input voltages are greater than the equalizing charging set
point voltage.
Over-charging and excessive gas precipitation may damage the battery plates and activate
material shedding on them. Too high (or too long) an equalizing charge may cause damage.
Please carefully review the specific requirements of the battery used in the system.
Certain types of batteries benefit from periodic equalizing charge, which can stir the electrolyte,
balance battery voltage and complete a chemical reaction. Equalizing charge increases the
battery voltage, higher than the standard complement voltage, which gasifies the battery
electrolyte. If the battery is being over discharged, the solar controller will automatically turn
to equalize charging stage, which lasts for 120 minutes. Equalize charge and boost charge
are not carried out constantly in a full charge process to avoid too much gas precipitation or
overheating of battery.
WARNING: Risk of explosion
NOTE: Equipment damage
NOTE: Equipment damage
10