8
Indoor unit installation
101mm(4.0in)
722mm (28.5in)
Left rear wall hole
65mm (2.5in)
230mm (9.1in)
190mm (7.5in)
Left rear wall hole
65mm (2.5in)
244mm(9.6in)
190mm(7.5in)
Left rear wall hole
65mm (2.5in)
165mm (6.5in)
106mm(4.2in)
Left rear wall hole
65mm (2.5in)
34
34 / 324 EN
/ 334
348.4mm (13.7in)
179mm (7.1in)
136mm (5.4in)
Indoor unit outline
Right rear wall hole
65mm (2.5in)
Model A
403mm (15.9in)
231mm (9.1in)
121mm (4.8in)
805mm (31.7in)
Right rear wall hole
65mm (2.5in)
Model B
418mm (16.5in)
246mm (9.7in)
121mm (4.8in)
835mm (32.9in)
Right rear wall hole
65mm (2.5in)
Model C
527mm (20.7in)
247mm (9.7in)
973mm(38.3in)
Right rear wall hole
Model D
65mm (2.5in)
199mm (7.8in)
129mm (5.1in)
1082mm (42.6in)
Left rear wall hole
90mm (3.54in)
389mm (15.3in)
172mm (6.8in)
52mm (2.05in)
Left rear wall hole
1259mm (49.55in)
90mm (3.54in)
Note: When the gas side
C
connective pipe is Ø16mm (5/8in)
or more, the wall hole should be
90mm (3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating sleeve
attached to the back of the unit. You must prepare
the piping before passing it through the hole in the
wall.
1. Based on the position of the wall hole relative to
the mounting plate, choose the side from which
the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit. This
will create a slot through which your piping can
exit the unit. Use needle nose pliers if the plastic
panel is too difficult to remove by hand.
Split type air conditioner / User Manual
Split type air conditioner / User Manual
603mm (23.7in)
322mm (12.7in)
173mm
(6.8in)
Right rear wall hole
Model E
90mm (3.54in)
643.6mm (25.3in)
257mm (10.1in)
332mm (13.05in)
Indoor unit outline
52mm (2.05in)
Right rear wall hole
90mm (3.54in)
Model F