5-2. Output Derating
100
80
60
40
20
0
-10
0
5-3. Mounting Method
(1) Forced air cooling type power supply.
This power supply has ventilating holes on the front
and back side panels. Keep these two areas freely as
much as possible.
(2) The maximum allowable penetration is 6mm.
Incomplete thread of mounting screw should not be
penetrated.
(3) Recommended torque for mounting screw :
M4 screw : 1.27 N · m( 13.0kgf · cm )
6. Wiring Method
(1) The output load line and input line shall be separated to improve noise sensitivity.
(2) The sensing lines shall be twisted and separated from the output lines for remote sensing.
(3) Use all lines as thick and short as possible to make lower impedance.
(4) Attaching a capacitor to the load terminals can eliminate noise.
(5) For safety and EMI considerations, connect
(6) Recommended torque for the terminal ;
HWS600 Output terminal (M5 screw) : 2.50 N · m (25.5kgf · cm )
HWS300 Input, Output terminal & HWS600 Input terminal (M4 screw) : 1.27 N · m (13.0kgf · cm )
[ The PHD connector manufacture method ]
This product is using SPHD-001T-P0.5 or SPHD-002T-0.5 connector made from JAPAN SOLDERLESS TERMINAL
MFG CO LTD.
Regarding to manufacture of a connector, it becomes the regulation as following.
a). Appricable Wire and Crimping tool
Wire size is AWG#26 ~ AWG#22 and insulation outer dia is φ 1 .0 ~ φ 1 .5 mm.
Appreciable wire per barrel size is UL1007 (standard wire ) and its equivalent standard wire can be used.
Regarding the AWG#22, use UL1061 or its equivalent standard wire,because wire insulation outer diameter
of UL1061 is samll.
Crimping tool is as below.
Crimping tool
AP-K2 or AP-KS
MKS-LS-10 or MKS-L-10
Mounting A,B
20
40
50
70
Ambient Temperature (
)
Crimping applicator
T a (
)
M o u n t i n g ( A )
-10 ~ +50
+70
More than 50mm
Air flow
Fan
Back Side