1
2
MENU
DEFAULT
Language selection:
Model selection:
Model name
Battery selection:
Reset count-meter
No reset
Display count-meter
Traction
Display Tune
Display Brightness
Solution Management
Wand/Spray Selection
Exit
Key-on Count-meter
Traction motor Count-
meter
Brushes motor Count-
meter
Vacuum motor Count-
meter
-ID CHECK- Password
To change the value of a parameter, proceed as follows:
1. Scroll through the sub-menus with buttons (1) and (2) until you find the parameter to be changed.
2. Use buttons (3) and (4) to scroll through the list of values available with regard to the parameter that you want to change.
3. To enable the change made, it is necessary to go back to the work menu; to exit the operator menu, select the exit sub-menu and confirm
using the button (5).
BROWSING THE COMMAND DISPLAY MENU
5
3s.
VALUES THAT
CAN BE SET
EN
IT / EN / FR / SP / DE This function enables the display language to be selected.
Pb60 / Gel60 / PPb /
Gel60
Pb80 / Gel80
No reset/ Reset
Traction / Key-On
15
5÷50
0
0÷10
None
None/FLR/FSS
None
None / Wand / Spray
N
Y/N
-
-
-
-
-
-
-
-
-
-
To access the menu screen, press the buttons (2) and (3), and
keeping these pressed down, turn on the machine. After the first
screen, the GENERAL MENU will appear.
To navigate through the menus, use the buttons:
3
Button (1) for scrolling to the next parameter.
Button (2) for scrolling to the next parameter.
Button (3) to increase the value selected by a unit.
4
Button (4) to decrease the value selected by a unit.
Button (5) to confirm the value to exit the operator menu.
DESCRIPTION
This function enables the machine model to be selected.
This function enables the type of battery that you wish to use on the
machine to be selected.
This function enables the hour meter which is visible on the display to be reset.
This function enables the type of hour meter to view on the display to be
selected. KEY-ON: connected to the ignition key. TRACTION: connected
to the traction motor.
This function allows the display contrast to be adjusted. The value goes
from a minimum of 5 to a maximum of 50, with unitary increments.
This function allows the display brightness to be adjusted. The value goes
from a minimum of 0 to a maximum of 10, with unitary increments.
This function enables the operator to select how to manage the detergent
product. None: The detergent used is managed manually by the operator.
FSS: the water and the detergent are dosed automatically by the machine.
FLR: this function enables the detergent solution to be continually
recycled.
This function allows the operator to activate or deactivate the liquid
vacuum wand or spray gun optional accessories. None: no optional
accessory. Wand: the liquid vacuum wand accessory function is active.
FLR: the spray gun accessory function is active.
This function enables the user to exit the operator menu.
This function enables the hour meter for overall machine use to be viewed
(this relates to the ignition key).
This function enables the overall hour meter for the traction motor to be
viewed.
This function enables the overall hour meter for the brush motor to be
viewed.
This function enables the overall hour meter for the suction motor to be
viewed.
This function enables the password to be entered, in order to access the
"advanced menu".
33