INSTALL GAS SUPPLY
General
Specifications
For Piping
Note: Contact your local municipality
for building codes regulating outdoor
gas barbecue
installations.
In absence
of Local Codes, you must conform
to
the latest edition
of the National Fuel Gas Code: ANSI Z 223.1/NFPA
54, or CAN/
CGA-B14g. 1, Natural Gas and Propane
Insta!lation Code. WE RECOMMEND
THAT THIS
INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements
taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA
54, or CAN/CGA-B149.1,
Natural Gas and
Propane Installation
Code for complete
specifications.
.
This barbecue is designed to operate at 7" of water column pressure (.2526 psi).
A manual shut-off valve must be installed outdoors, immediately
ahead of the quick
disconnect.
An additional
manual shut-off valve indoors should be installed in the branch fuel line
in an accessible location
near the supply line.
The quick disconnect
connects to a 3/8" NPT thread from the gas source.The
quick
disconnect
fitting is a hand-operated
device that automatically
shuts off the flow of
gas from the source when the barbecue
is disconnected.
The quick disconnect
fitting can be installed horizontally,
or pointing downward.
Installing the fitting with the open end pointing upward can result in collecting water
and debris.
The dust covers (supplied
plastic plugs) help keep the open ends of the quick
disconnect
fitting clean while disconnected.
Pipe compound
should be used which is resistant to the action of natural gas when
connections
are made.
The outdoor connector
must be firmly attached to rigid, permanent
construction.
z_ WARNING:
Do not route the ten foot hose under a deck. The
hose must be visible.
Gas
Line Piping
.
For the correct size and length of gas line piping refer to the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA
54, or CAN/CGA-B149.1,
Natural Gas
and Propane Installation
Code.
.
Gas piping may be copper tubing, type K or L; polyethylene
plastic tube, with a
minimum wall thickness of .062"; or standard weight (schedule 40) steel or wrought
iron pipe.
.
Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen
sulfide per 100 cubic feet of gas.
.
Plastic tubing is suitable only for outdoor, underground
use.
.
Gas piping in contact with earth, or any other material which may corrode the piping,
must be protected against corrosion
in an approved manner.
.
Underground
piping must have a minimum of 18" cover.
Test
Connections
All connections
and joints must be thoroughly tested for leaks in accordance
with local
codes and all listed procedures
in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA
54, or CAN/CGA-B149.1.
This is a typical
installation
of a Weber ®natural
gas barbecue.
Local codes may require different
installations.
1
Gas Supply
2
Shut off
3
Quick-Disconnect
4
3/8" Pipe Nipple
5
Reducing Coupling
6
1/2" Pipe Nipple
7
Locking Shut Off
8
Do Not Use
DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames
in the area while you
check for gas leaks. This will result in a fire or explosion
which can cause serious
bodily injury or death and damage