Check:
A)
Flexible Hose to bulkhead connection
(1).
B)
Main gas line to bulkhead connection
(2).
C)
Main gas line to manifold connections
(3).
z_ WARNING:
If there is a leak at connection (1,2, or 3),
retighten
the fitting
with a wrench and recheck for leaks with
soap and water solution. If a leak persists after re=tightening
the fitting,
turn OFF the gas. DO NOT OPERATE THE GRILL.
Contact
the Customer
Service Representative
in your area
using the contact
information on our web site.
Log onto www.weber.com
®.
D)
Flexible Hose to Quick Disconnect
connection
(4).
E)
Valves to manifold connections
(5).
z_ WARNING:
If there is a leak at connections
(4 or 5), turn
OFF the gas. DO NOT OPERATE THE GRILL. Contact the
Customer
Service Representative
in your area using the
contact information on our web site.
Log onto www.weber.com
®.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections
with water.
Reinstall Control
Panel
You will need: Phillips screwdriver.
F)
Position top edge of control panel on tabs of frame. Push down into position.
G)
Reinstall igniter module.
H)
Slide both shorter wind deflector tabs toward inside edge of control panel while you
slide longer tab over outside edge. Seek previous
illustrations for reference.
I)
Line up screws with screw holes on both control panel bracket and frame.
J)
Tighten screws.
K)
Place corresponding
control knobs onto valve stems. ®
The grill illustrated
may
have slight differences
than the model
purchased.
11