Remove
Control
Knobs
& Control
Panel
For LeakTesting
You will need: Phillips screwdriver.
A)
Remove control knobs, igniter button, retention nut, and battery (1).
B)
Remove screws from wind deflector with a Phillips screwdriver
(2).
C)
Tilt end of wind deflector down and slide wind deflector away to remove (3).
D)
Let igniter module dangle from wires. Do not disconnect
(4).
E)
Remove screws from underside
of control panel with Phillips screwdriver
(5).
F)
Lift control panel up slightly, tilt up front edge and gently lift up (6).
G)
Replace control panel and wind deflector when leak check is completed.
÷
CHECK
FOR
GAS
LEAKS
DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames
in the area while you
check for leaks. Sparks or open flames will result in a fire or
explosion, which can cause serious bodily injury or death
and damage to property.
Note: All factory-made
connections
have been thoroughly
checked
for gas leaks. The
burners have been flame-tested.
As a safety precaution
however, you should recheck all
fittings for leaks before using your Weber- gas barbecue.
Shipping
and handling
may
loosen or damage
a gas fitting.
WARNING:
The gas connections
of your gas grill have been
factory
tested. We do however
recommend
that you leak
check all gas connections before operating your gas grill.
WARNING:
Perform
these leak checks even if your barbecue
was dealer or store assembled.
If your grill has a side burner make sure the side burner is turned off.
Turn on gas supply at source.
WARNING:
Do not ignite burners
when leak checking.
You will need: A soap and water solution and a rag or brush to apply it.
A)
Mix soap and water.
B)
Turn on gas supply (1).
C)
Check for leaks by wetting the fitting with the soap and water solution and watching
for bubbles. If bubbles form, or if a bubble grows, there is a leak.
if there is a leak, turn off the gas and tighten
the fitting. Turn the gas back on and
recheck with the soap and water solution.
If leak does not stop do not use the
barbecue.
Contact
the customer
service
representative
in your area using
the
contact
information
on our web site. Log onto www.weber.com
®.
D)
When leak checking
is complete,
turn gas supply off at the source and rinse
connections
with water.
Note: Since some leak test solutions, including
soap and water, may be slightly
corrosive, a!l connections
should be rinsed with water after checking
for leaks.
WARNING:
You should check for gas leaks every time you
disconnect and reconnect
a gas fitting.