PARTS INCLUDED FOR INSTALLATION (parts are not to
scale):
3 ea Hex Nuts (#38)
3 ea Lock Washers (#37)
3 ea Flat Washers (#36)
3 ea Anchors (#31)
INSTALLATION INSTRUCTIONS:
1. Select the desired installation location. Run supply wires from the breaker
panel to the desired location and prepare the concrete surface. (If you are
unfamiliar with proper electrical practices, obtain services of a qualified
electrician.) When preparing the concrete surface, be sure that the Wire
Conduit (#27), protecting the supply wires, extends 1/2" above the Concrete
Surface (#28) to prevent any runoff from entering. Using the provided
Template (#29), mark the locations for the mounting holes. At the marked
locations, drill ½" diameter Holes (#30) approximately 3" deep. Do not
exceed a 3" depth. (Fig. 9)
2. Insert the Anchors (#31) into the Holes (#30). (Fig. 10)
3. Using the provided Wire Nuts (#9), make the following wire connections (Fig.
11):
White Extension Wire (#7)
Black Extension Wire (#8)
Fixture Ground Wire (#15)
Page 10
to
White (Neutral) Supply Wire (#33)
to
Black (Hot) Supply Wire (#34)
to
Supply Ground Wire (#35)
1 ea Template (#29)
3 ea Wire Nuts (#9)