Technical specifications
series10
Operating voltage
Load current
Output
Length of output pulse
Reverse polarity protection
Short circuit protection
Voltage drop
Power consumption at 24 V
Operating temperature
Degree of protection IP
Degree of protection IK
Degree of contamination
Communication interface
Control voltage E1/E2
Measuring principle
Type of actuation
Actuation force
Max. altitude
Relative air humidity
DC 24 V (8.4 to 32 V)
max. 200 mA
Adjustable PNP / NPN; NO / NC
Adjustable
Protection of all cables/lines
Protected against short circuit and overload
Max. 5 V at 200 mA load current
Max. 40 mA
-30 °C (-22 °F) to +65 °C (149 °F)
Front side IP6K9K maximum unevenness in mounting surface
< 0.1 mm
Back M12: IP67 IP68
Back strands: IP20
IK08
2
IO-Link specification V1.1
on 80%U V +
off 0 to 20% U V +
Capacitive
Touch
No actuation force required
2000 m above sea level with "CSA listing"
Max. 95%, non-condensing